AC Infinity SUNCORE S3 | 幼苗加热垫,带加热控制器 | IP-67 防水 | 10 英寸 x 20.75 英寸

AC Infinity  |  库存单位: AC-SMS3
正常价格 $21.99
结账时计算运费

  • Ships in 1-4 business days
  • Ships with 'Signature Required' at delivery

Ask an Expert (888) 378-0017

Unlock Trade Pricing

Join our commercial tier for bulk pricing and inventory alerts.

Yield AI
15 questions per session Grow systems advisor · cannafullspec.com

描述

The SUNCORE S3 is a 10" x 20.75" far-infrared seedling heat mat with integrated temperature controller, engineered for craft propagation operators who require repeatable rhizosphere thermal conditions without manual cycling — replacing uncontrolled fixed-output mats that force operators to choose between overheating and cold stress.

  • Outcome: Consistent substrate temperature maintained within a controlled band of 80–87°F (27–31°C), eliminating thermal variance that degrades germination uniformity across a tray.
  • Replaces: Fixed-output heat mats with no temperature regulation, manual on/off cycling, and unprotected cord connections vulnerable to moisture damage.
  • Environment: Indoor propagation stations, basement germination racks, terrarium enclosures, and controlled-environment seedling benches operating on standard 100–125V AC circuits.

FACTORY-AUTHORIZED DEALER — CANNAFULL SPECTRUM SOLUTIONS

Deployed in licensed commercial facilities across the United States.

Quick Spec: SKU: AC-SMS3  |  10 x 20.75 in. (25.4 x 52.7 cm)  |  20W  |  100–125V AC  |  IP-67  |  Far-Infrared Film  |  UL: E518635  |  MET: E115128

Precision Control in Any Space.

The real cost of uncontrolled propagation heat is not a single failed tray — it is the compounding variance that accumulates across every cycle when the operator has no mechanism to hold substrate temperature steady. Fixed-output mats run hot when ambient conditions are warm and cold when they are not, forcing a choice between manual cycling and thermal drift. Manual cycling introduces the exact oscillation that damages emerging root tissue: a sharp temperature drop followed by a spike, repeated until germination rates fall below acceptable thresholds and the operator absorbs the loss as a cost of doing business. That silent tax — paid in uneven emergence, extended propagation timelines, and trays that never reach uniform canopy density — is the direct consequence of equipment that offers no feedback loop and no control authority.

After deployment of the SUNCORE S3, the propagation station operates on a defined thermal set point rather than ambient luck. The controller holds substrate temperature within the 80–87°F (27–31°C) operating band continuously, without operator intervention between checks. Trays emerge at uniform rates because every cell in the tray is receiving the same thermal input from the same surface. The propagation timeline becomes predictable, the labor requirement for monitoring drops, and the operator regains the scheduling certainty that uncontrolled equipment permanently removes from the workflow.

The mechanism that makes this possible is a far-infrared film heating element laminated into a quad-layer PVC body rated IP-67 for full dust and temporary submersion protection. Far-infrared emission delivers heat as radiant energy absorbed directly by the substrate rather than conducted through a wire coil, producing a softer, more even thermal output across the full 10" x 20.75" surface. The controller allows the operator to set and maintain temperature over time without cycling the mat on and off — eliminating the thermal oscillation that source data identifies as a direct cause of seed rot. The power cord connection is individually sealed against moisture ingress, and all seams are sealed to prevent water and dust penetration. Operating voltage is 100–125V AC with a maximum draw of 20W and a 60-inch power cord. Certifications are UL (E518635) and MET (E115128). In practical terms, the SUNCORE S3 delivers up to 20°F above ambient temperature across a 10" x 20.75" surface at 20W on a standard 100–125V AC wall outlet.

Where This Belongs (and Doesn't)

The SUNCORE S3 operates on standard 100–125V AC circuits. It is not a high-voltage industrial heating element and does not require dedicated circuit installation. Consult a licensed electrician before deploying multiple units on a shared circuit. This product is not rated for outdoor or continuously submerged use despite its IP-67 rating.

Deployment Contexts

  • Indoor propagation benches and seedling racks
  • Basement germination stations with cold concrete surfaces
  • Controlled-environment terrarium and clone propagation setups
  • Standard 1020 flat tray configurations (10" x 20.75" footprint)
  • Fermentation and culture applications requiring stable low-range heat

Not Recommended For

  • Outdoor or permanently wet environments
  • Applications requiring temperatures above 87°F (31°C) substrate surface
  • High-voltage or 240V circuit installations
  • Continuous submersion beyond IP-67 transient rating
  • Unattended operation without a functioning temperature controller

How It Works

The SUNCORE S3 generates heat through a far-infrared film element rather than a resistive wire coil. Far-infrared emission transfers thermal energy as radiant output absorbed directly by the material above the mat — in this case, the growing medium inside the tray — rather than relying on conductive transfer through air or contact layers. The practical result is a softer, more even heat distribution across the full surface area with fewer localized hot spots than wire-coil designs produce. The mat body is constructed from multiple layers of PVC matting with the heating film laminated internally, producing a flexible, wear-resistant surface that can be wiped clean between propagation cycles.

The IP-67 waterproof rating is achieved through sealed seam construction along all mat edges and a specially sealed power cord connection point — the two primary ingress vectors on any heat mat operating in a moisture-present propagation environment. IP-67 certifies the unit against complete dust ingress and temporary immersion in water up to 1 meter for 30 minutes, providing a meaningful margin of protection against irrigation overspray, condensation, and incidental liquid contact during routine tray management. The 60-inch power cord provides adequate reach from bench surface to wall outlet without extension cord dependency in standard rack configurations. The controller paired with the S3 allows the operator to set a target temperature and maintain it continuously — holding the substrate within the 80–87°F (27–31°C) operating band without manual on/off intervention, which source data confirms is the primary mechanism by which uncontrolled cycling causes seed rot. In practical terms, the SUNCORE S3 delivers a steady, far-infrared radiant heat output across a 10" x 20.75" surface at 20W maximum draw, maintaining substrate temperature up to 20°F above ambient on a 100–125V AC circuit with UL certification E518635 and MET certification E115128.

Commercial Assurance

The SUNCORE S3 carries dual third-party electrical safety certifications: UL (E518635) and MET (E115128). These certifications confirm the unit has been independently evaluated against applicable electrical safety standards for commercial and institutional deployment in the United States. IP-67 waterproof rating is a manufacturer-specified and independently verifiable ingress protection classification under IEC standard 60529.

  • UL Certification: E518635
  • MET Certification: E115128
  • Waterproof Rating: IP-67 (dust-tight; temporary immersion to 1m/30 min)
  • Warranty: Not specified in source data — contact Cannafull Spectrum Solutions or the manufacturer directly for current warranty terms before purchase.
  • Operating Jurisdiction: Cannafull Spectrum Solutions ships within the contiguous 48 United States only.

System Integration

  • Tray Compatibility: Footprint matches standard 1020 propagation flat dimensions (10" x 20.75"), enabling direct integration with existing tray inventory without modification.
  • Controller Architecture: The included temperature controller eliminates the need for a separate external thermostat, reducing component count and potential failure points in the propagation station.
  • Circuit Load: At 20W maximum draw on 100–125V AC, multiple S3 units can be deployed on a single standard 15A circuit without approaching load limits — verify total circuit load before deployment.
  • Moisture Environment Compatibility: IP-67 seam-sealed construction and sealed cord connection allow integration into propagation environments where irrigation overspray and condensation are routine operational conditions.
  • Ecosystem Scalability: The SUNCORE S3 is the controller-equipped entry point in the SUNCORE propagation mat ecosystem; operators requiring expanded coverage or multi-tray configurations can scale to T-Series or A3X2 dual-mat configurations within the same product family.

Facility Integration Data — ROI Reference

The following table provides a fleet-scale reference for electrical load planning and procurement budgeting. Power draw figures are based on verified source data (20W maximum per unit). Cost estimates use MAP pricing of $21.99 per unit.

Fleet Size Total Max Draw (W) 15A Circuit Capacity (units) Procurement Cost (MAP)
10 Units 200W ~8 units per circuit at 80% load rule $219.90
20 Units 400W ~8 units per circuit at 80% load rule $439.80
50 Units 1,000W ~8 units per circuit at 80% load rule $1,099.50

Circuit capacity estimates apply the NEC 80% continuous load rule to a standard 15A/120V circuit (1,440W usable). Actual circuit allocation must be verified by a licensed electrician prior to deployment. Procurement cost based on MAP $21.99; actual invoiced pricing may vary.

Operator Field Notes

  • Controller dependency: The temperature control benefit of the S3 is only realized when the included controller is used as intended. Operating the mat without the controller — or bypassing it — removes the set-point regulation that prevents thermal oscillation and associated seed rot risk.
  • Cold surface insulation: Deploying the mat on concrete or metal bench surfaces without an insulating layer beneath it will reduce effective substrate temperature output, as the mat will lose heat downward. A thin foam or cork insulating pad between the mat and the bench surface improves upward heat delivery efficiency.
  • Cleaning protocol: The IP-67 quad-layer PVC surface is designed to be wiped clean between cycles. Do not use abrasive scrubbers or solvent-based cleaners that may degrade the PVC outer layer or compromise seam sealing over time.
  • Cord management: The 60-inch power cord is sealed at the connection point. Do not modify, splice, or extend the cord. Route the cord away from standing water accumulation points even given the IP-67 rating.
  • Temperature range ceiling: The S3 operating range tops at 87°F (31°C). Applications requiring substrate temperatures above this threshold are outside the rated operating envelope of this unit.
  • Multi-unit deployment: When deploying multiple S3 units on a single propagation rack, verify that each unit is on a circuit with adequate remaining capacity. Do not daisy-chain power strips without confirming the strip's rated load capacity against total mat draw.

Operator FAQ

Q: What is the temperature range the SUNCORE S3 can maintain, and is that the mat surface temperature or the substrate temperature?

A: The SUNCORE S3 is rated to operate within a temperature range of 80–87°F (27–31°C) and is specified to raise temperature up to 20°F above ambient. This refers to the heat output capability of the mat surface. Actual substrate temperature will vary based on ambient room temperature, tray depth, growing medium type, and whether an insulating layer is used beneath the mat. Operators should verify substrate temperature with a calibrated probe thermometer during initial deployment to confirm the mat is achieving target rhizosphere conditions in their specific environment.

Q: Does the SUNCORE S3 include a temperature controller, and what does the controller allow the operator to do?

A: Yes. The SUNCORE S3 (SKU: AC-SMS3) includes a temperature controller. The controller allows the operator to set a target temperature and maintain it continuously without manually cycling the mat on and off. This is the critical functional distinction of the S3 relative to the A-Series models in the SUNCORE lineup, which operate via direct AC plug connection only and do not include a controller. Continuous temperature regulation via the controller eliminates the thermal oscillation that source data identifies as a cause of seed rot during germination.

Q: What does IP-67 mean in the context of a seedling heat mat, and does it mean the mat can be submerged?

A: IP-67 is an ingress protection rating under IEC standard 60529. The "6" indicates complete protection against dust ingress. The "7" indicates protection against temporary immersion in water up to 1 meter depth for up to 30 minutes. In a propagation context, this means the mat is protected against irrigation overspray, condensation accumulation, and incidental liquid contact during routine tray management. It does not mean the mat is rated for continuous submersion or for use in permanently wet environments. The S3 achieves this rating through sealed seam construction and a specially sealed power cord connection point.

Q: Why does the SUNCORE S3 use far-infrared film instead of a wire coil heating element?

A: Far-infrared film delivers heat as radiant energy that is absorbed directly by the material above the mat rather than relying on conductive transfer through contact layers. This produces a softer, more even heat distribution across the full mat surface compared to wire coil designs, which tend to create localized hot zones along the coil path. Even heat distribution across the full 10" x 20.75" surface means every cell in a standard 1020 tray receives consistent thermal input, reducing within-tray germination variance. The far-infrared film is laminated into the multi-layer PVC body, contributing to the mat's flexibility and durability.

Q: How many SUNCORE S3 units can be operated on a single standard 15A circuit?

A: At 20W maximum draw per unit on a 100–125V AC circuit, and applying the NEC 80% continuous load rule to a standard 15A/120V circuit (usable capacity approximately 1,440W), approximately 8 units can be operated per circuit before reaching the 80% threshold. This is a planning estimate only. Actual circuit allocation must account for all other loads on the circuit and must be verified by a licensed electrician prior to multi-unit deployment. Do not rely on this estimate as a substitute for a qualified electrical assessment.

Q: What is the warranty on the SUNCORE S3, and what certifications does it carry?

A: The warranty period for the SUNCORE S3 is not specified in the available source data. Buyers should contact Cannafull Spectrum Solutions or the manufacturer directly to confirm current warranty terms before completing a purchase. The SUNCORE S3 carries dual third-party electrical safety certifications: UL certification number E518635 and MET certification number E115128. These certifications confirm independent evaluation against applicable electrical safety standards for deployment in the United States.

Shipping & Logistics

  • Shipping Jurisdiction: Cannafull Spectrum Solutions ships within the contiguous 48 United States only. Orders to Alaska, Hawaii, U.S. territories, or international destinations cannot be fulfilled through this storefront.
  • Fulfillment Timeline: Standard processing and carrier transit times apply. Contact Cannafull Spectrum Solutions directly for current lead time estimates on single-unit and multi-unit orders.
  • Returns: Returns are accepted subject to the conditions outlined in the Cannafull Spectrum Solutions Return Policy. Products must be in original, uninstalled condition to qualify for return consideration. Review full terms at cannafullspec.com/pages/return-policy before ordering.
  • Restocking Fee: Returns of non-defective items are subject to a restocking fee of up to 25% per our Return Policy. Review full terms at cannafullspec.com/pages/return-policy before ordering.

Questions about your order? Contact Cannafull Spectrum Solutions directly through the store contact page before initiating a return or freight claim.

What's in the Box

  • 1x SUNCORE S3 Far-Infrared Seedling Heat Mat — 10" x 20.75" (25.4 x 52.7 cm)
  • 1x Temperature Controller (included with S3; enables set-point regulation without manual cycling)
  • 60-inch sealed power cord (integrated; not a separate accessory)

Box contents confirmed from available source data. If your shipment is missing any listed component, contact Cannafull Spectrum Solutions before use. Do not assume missing components will be shipped separately without prior confirmation.

Regional Compliance & Deployment Notes

  • Electrical Certification: The SUNCORE S3 carries UL (E518635) and MET (E115128) certifications applicable to electrical safety standards for the United States market.
  • Operating Voltage: Rated for 100–125V AC only. Not compatible with 240V circuits without a step-down transformer — consult a licensed electrician before any non-standard installation.
  • NEC Compliance: Multi-unit deployments must comply with applicable National Electrical Code (NEC) requirements for continuous load circuits. The 80% continuous load rule applies to circuit capacity planning for propagation rack installations.
  • Licensed Facility Use: Operators deploying the SUNCORE S3 in licensed cultivation or processing facilities should verify that the unit's electrical certifications satisfy any facility-specific equipment approval requirements imposed by their state licensing authority.
  • Shipping Jurisdiction: Available for deployment in licensed commercial facilities across the contiguous United States. Cannafull Spectrum Solutions does not ship to Canadian provinces or international destinations.

Product specifications, certifications, and warranty terms are subject to change by the manufacturer without notice. Cannafull Spectrum Solutions makes no independent warranty representations beyond those provided by the manufacturer. Verify all compliance requirements with your facility's licensed electrical contractor and applicable state regulatory authority prior to deployment. Warranty period not specified in available source data — confirm directly with manufacturer or Cannafull Spectrum Solutions before purchase.

规格

  • Product Category
    幼苗加热垫

Route Package Protection

在 CannaFull Spectrum Solutions,我们明白在运输过程中安心是至关重要的。这就是为什么我们自豪地为您的所有在线订单提供全面的运输保护和跟踪解决方案 Route!

Route:您的一体化运输中心

Route 与您的 CannaFull Spectrum Solutions 购物体验无缝集成,让您完全掌控配送过程,安心无忧。以下是 Route 提供的功能:

  • 自动包裹保护:在 CannaFull Spectrum Solutions 上下的每个订单都会自动附带 Route 的基本保护计划,保护您的购买免遭包裹丢失、被盗或损坏。
  • 增强型跟踪: Route 超越了基本跟踪信息。获取实时更新、预计交付时间以及有关潜在延误或问题的主动警报。
  • 轻松的索赔管理:如果您的包裹遇到问题,Route 可简化索赔流程。直接通过 Route 应用提出索赔,即可快速高效地获得解决方案。
  • 价格匹配保证: Route 可确保您获得最优惠的价格。如果您在一定时间内(通常为 48 小时)发现同一商品的广告价格更低,Route 将退还差价。
  • 丢失邮件更换: Route 提供额外的安全保障。如果您的包裹被标记为已送达但您从未收到,Route 可能会更换它,具体取决于具体物品和承保选项。

使用大麻全光谱解决方案路线的好处:

  • 放心购物:知道您购买的商品不会丢失、被盗或损坏,您就可以完全放心购物。
  • 轻松跟踪:利用 Route 的实时跟踪和主动通知随时了解每一步情况。
  • 轻松索赔: Route 简化了索赔流程,在您遇到任何与交付相关的问题时,可为您节省时间并避免烦恼。
  • 每次购买都增加价值: Route 会自动为您的 [您的商店名称] 订单提供基本保护和有价值的跟踪功能,无需支付额外费用。

如何开始路线:

使用 Route 购买 CannaFull Spectrum Solutions 简单又方便:

  1. 完成您的订单:当您在 CannaFull Spectrum Solutions 结账时,您将看到激活 Route 对您的订单的保护的选项(通常是预先选择的)。
  2. 下载路线应用程序:为了获得更加无缝的体验,请下载适用于 iOS 和 Android 的免费路线应用程序。
  3. 追踪您的包裹:登录路线应用程序或查看您的电子邮件以获取追踪更新并管理您的受保护货件。

Route:您的无忧运输合作伙伴

CannaFull Spectrum Solutions 致力于通过每次购买提供 Route 服务,为您提供无压力的购物体验。Route 让您可以放心购物,因为您知道您的包裹受到保护,并且每一步都可以轻松跟踪。

常见问题:

  • Route 是免费的吗? CannaFull Spectrum Solutions 的每笔订单都会自动包含基本 Route 保护。Route 还提供具有附加功能和覆盖范围的可选高级计划。
  • 如何向 Route 提出索赔?可通过 Route 应用程序或网站轻松提出索赔。
  • 如果我的包裹丢失了怎么办?根据具体情况和您选择的保险计划,Route 可能会赔偿您或更换丢失的物品。

放心购物,轻松追踪!选择 CannaFull Spectrum Solutions,在下次在线购物时体验 Route 的强大功能。

Shiping, Cancelations & Returns

订单处理:我们努力在 1-2 个工作日内处理所有订单。
运费和方式:我们提供多种运输方式以满足您的需求和预算。预计交货时间将在结账时显示,并可能因您选择的方式和位置而异。
  • 标准运费(预计 3-5 个工作日内送达):X 美元(Y 美元以上订单免费)
  • 加急运输(预计 1-2 个工作日内送达):$Z

国际运输(如适用):我们目前提供/不提供国际运输。(如果您提供,请注明费率和预计交货时间)。

追踪和路线保护:订单发货后,您将通过电子邮件收到带有追踪号的通知。我们还与 Route 合作,在结账时为所有订单提供额外的运输保护(包裹丢失、被盗或损坏),只需支付少量费用。

请注意:由于代发货的特性,送货时间可能比其他商店宣传的稍长。我们努力提供尽可能准确的估算,但可能会出现不可预见的情况。

取消政策

我们理解计划可能会发生变化,因此您可以在下单后 24 小时内取消订单并获得全额退款。如果您的订单已转发给我们的履行合作伙伴,我们将尽力满足您的取消请求,但可能会收取全额取消费或商店信用额。

退货政策

我们希望您对所购商品完全满意。如果您出于任何原因不满意,您可以在购买之日起 30 天内退回符合条件的商品。

符合条件的商品:大多数全新、未使用、未开封且带原包装的商品均符合退货条件。例外情况可能包括(如适用,请列出任何例外情况,例如最终销售商品或易腐烂商品)。

退货条件:要获得全额退款,退回的商品必须是未使用状态,且所有原始标签和包装完好无损。

退货运费:如果退货是由于我们的错误(例如,寄送了错误的商品)造成的,我们将承担退货运费。否则,您将承担退货运费。但是,您可以使用 Route 的保护计划(如果购买)来补偿丢失、被盗或损坏包裹的退货运费。

退款流程:收到您退回的商品并核实其状况后,我们将在 X 个工作日内处理您的退款。退款将以您原来的付款方式或商店信用额度发放,具体取决于您的偏好。

通过在我们这里购物,您同意本运输、取消和退货政策中概述的条款。

Warranty

在 CannaFull Spectrum Solutions,我们希望您对购买的产品充满信心。我们提供的许多 LED 生长灯都附带制造商保修,确保您的投资得到保护。

了解您的保修:

  • 具体保修条款和条件将根据您购买的个别产品而有所不同。
  • 我们强烈建议您在收到产品时查看随附的制造商保修信息。
  • 该信息通常详细说明保修期、保险范围和索赔流程。

帮助中心:

虽然保修由制造商直接处理,但我们理解处理保修索赔有时会令人困惑。在 CannaFull Spectrum Solutions,我们在整个过程中为您提供支持:

  • 轻松访问保修信息:我们努力在每个产品页面上提供清晰简明的保修信息。这通常包括可下载的保修文件或制造商保修网站的链接。
  • 专属客户支持:如果您对产品保修有任何疑问或需要帮助提出索赔,请随时联系我们友好的客户支持团队。我们将很乐意指导您完成整个流程,并帮助您从制造商处获得应有的支持。

我们能做什么:

虽然我们不能直接处理保修索赔,但我们可以通过以下几种方式为您提供帮助:

  • 帮助找到您的特定产品的相关保修信息。
  • 提供制造商保修部门的联系方式。
  • 提供有关完成和提交保修索赔的指导。
  • 充当您和制造商之间的联络人,让您随时了解整个过程。

我们对您的承诺:

CannaFull Spectrum Solutions 致力于提供积极的客户体验。我们希望您对购买的产品感到满意,这包括确保您的保修索赔得到迅速有效的处理。

Payment & Security

Payment methods

  • American Express
  • Diners Club
  • Discover
  • Google Pay
  • JCB
  • Mastercard
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.