The Alien V-SYSTEM 6 Pot 2 Row Kit is a recirculating deep water culture irrigation system engineered for craft operators who require consistent nutrient delivery, configurable layout, and automated top-feed management across a 6-plant, 2-row footprint.

  • Outcome: Uniform nutrient saturation and oxygen delivery across all 6 V-POTs via a closed-loop recirculating reservoir system with no air pump requirement.
  • Replaces: Manual top-feed schedules, passive reservoir systems, and disconnected irrigation setups that introduce run-to-run variance.
  • Environment: Designed for controlled-environment production spaces — grow tents, dedicated cultivation rooms, and compact licensed facilities where floor footprint is a managed variable.

FACTORY-AUTHORIZED DEALER — CANNAFULL SPECTRUM SOLUTIONS

Deployed in licensed commercial facilities across the United States.

SKU: BD100-0206  |  Configuration: 2 Rows / 6 V-POTs  |  Total Fluid Volume: 374.5 L (98.9 gal)  |  Pump: 250W / 11,700 L/h  |  Price: $2,808.38

Precision Control in Any Space

When irrigation infrastructure is unreliable, every cycle becomes a liability. Operators running disconnected or passive systems absorb the cost silently — in uneven canopy development, inconsistent root-zone oxygen levels, and manual intervention that compounds labor overhead with each feed event. Equipment that requires constant adjustment, lacks integrated filtration, or forces a fixed room layout doesn't fail dramatically; it erodes output gradually, cycle after cycle, until variance becomes the baseline expectation rather than the exception. That is the real cost of guesswork built into the infrastructure itself.

After deploying the V-SYSTEM, the operational picture changes at the infrastructure level. Nutrient solution moves through a closed recirculating loop with consistent pressure and flow, reaching each V-POT without manual intervention between feed cycles. Oxygen saturation is maintained through Venturi injector action — no secondary air pump required, no additional electrical draw, no additional failure point. The reservoir auto-tops via float valve, eliminating the manual monitoring that consumes technician time. The layout adapts to the room rather than forcing the room to adapt to it, with four distinct configuration options that allow the header and pump to be positioned inside or outside the cultivation space.

The mechanism behind that operational stability is a 250W V-SYSTEM Vortex Water Pump running at 120V with a flow rate of 11,700 L/h, circulating nutrient solution through a 374.5-liter (98.9-gallon) total fluid volume across six 58-liter (15-gallon) V-POTs arranged in two rows. Dual-Flow™ 5" fittings and 5" spiral tubing maintain hydraulic balance across the distribution network, while T304 stainless clamps and integrated filtration protect system integrity at every connection point. Push-fit feed connections reduce assembly time and eliminate leak points associated with threaded fittings under recirculating pressure. In practical terms, the Alien V-SYSTEM 6 Pot Kit delivers 11,700 L/h of recirculating flow across a 6-plant, 2-row layout at 250W / 120V with zero air pump dependency.


Where This Belongs (and Doesn't)

Electrical and plumbing infrastructure must be verified by a qualified technician prior to installation. The V-SYSTEM Vortex Water Pump operates at 120V / 250W and requires a dedicated, properly grounded circuit. Confirm floor drainage capacity and reservoir placement clearances before finalizing layout selection.

Optimal Deployment Environments

  • Controlled-environment grow tents (layout variants MIH, MSP optimized for compact footprints)
  • Dedicated cultivation rooms with external reservoir/header placement (variants MOL, MOR)
  • Licensed craft production facilities operating 6-plant recirculating systems
  • Facilities transitioning from passive or manual drain-to-waste irrigation to automated recirculating infrastructure

Not Recommended For

  • Facilities requiring more than 6 active plant sites without additional system expansion
  • Installations without access to a dedicated 120V / 250W grounded circuit
  • Environments where floor drainage or reservoir drainage cannot be confirmed prior to setup
  • Operations requiring certified pressure-rated plumbing connections under local code (verify with facility engineer)

How It Works

The V-SYSTEM operates as a recirculating deep water culture (RDWC) platform. Nutrient solution is held in a central reservoir and driven by the V-SYSTEM Vortex Water Pump — rated at 250W, 120V, and 11,700 L/h — through a closed-loop distribution network to each of the six V-POTs. Each V-POT holds 58 liters (15 gallons), and the total system fluid volume is 374.5 liters (98.9 gallons) across the 2-row configuration. This volume-to-plant ratio supports stable nutrient concentration and temperature buffering across the full irrigation cycle.

Oxygen delivery is handled by Venturi injectors integrated into the flow path. As nutrient solution passes through the Venturi geometry, atmospheric oxygen is drawn directly into the fluid stream — eliminating the need for a separate air pump and the associated tubing, airstones, and electrical load. This is a passive oxygenation mechanism driven entirely by pump pressure, which means oxygen saturation scales with flow rate rather than requiring independent calibration. Integrated filtration protects the Venturi injectors and pump inlet from particulate contamination, extending service intervals and protecting hydraulic performance.

Distribution hardware includes 5" Dual-Flow™ fittings and 5" spiral tubing, which maintain consistent hydraulic resistance across all six feed lines. T304 stainless clamps secure all connections under recirculating pressure, and push-fit feed connections allow rapid assembly and disassembly without tools. Inspection covers on each V-POT provide access to root zones and connection points without disrupting the active irrigation cycle. A water fill line on the reservoir and a float valve for automatic top-off maintain fluid volume between manual reservoir service intervals, reducing the frequency of hands-on intervention required during active production cycles. In practical terms, the Alien V-SYSTEM 6 Pot Kit circulates 374.5 liters of nutrient solution at 11,700 L/h through six 58-liter V-POTs across a 2-row layout, with passive Venturi oxygenation and automatic reservoir top-off operating continuously at 250W / 120V.


Configuration Decoder — Layout Variants

The V-SYSTEM 6 Pot Kit ships in four layout configurations. All variants share identical fluid volume, pump specifications, V-POT capacity, and pricing. The only variable between configurations is the assembled footprint — determined by header and pump placement relative to the cultivation space. Select the variant that matches your room geometry before ordering.

Variant Code Layout Description Max Length (in) Max Width (in)
MIH Header and pump positioned for maximum internal compactness 76⅜" 56¾"
MOL Header and pump offset to the left for external placement 95½" 65½"
MOR Header and pump offset to the right for external placement 93⅞" 65½"
MSP Split configuration for space-optimized internal header routing 92⅜" 52¾"

All variants: 2 rows, 6 V-POTs, 374.5 L total fluid volume, 250W / 120V / 11,700 L/h pump, $2,808.38 USD. Confirm your room dimensions against the assembled footprint of your selected variant before finalizing your order.


Commercial Assurance

  • Factory-Authorized Distribution: Cannafull Spectrum Solutions is an authorized dealer for the Alien V-SYSTEM product line. All units are sourced through verified supply channels.
  • Warranty Status: Warranty terms for SKU BD100-0206 are not specified in available manufacturer source data. Contact Cannafull Spectrum Solutions prior to purchase to confirm current warranty coverage directly with the manufacturer.
  • Component Integrity: T304 stainless clamps, Dual-Flow™ fittings, and integrated filtration are production-grade components specified for recirculating pressure environments — not consumer-grade substitutes.
  • Pump Specification: The V-SYSTEM Vortex Water Pump (JET-STREAM® Vortex™) is rated at 250W / 120V / 11,700 L/h and is matched to the hydraulic requirements of the 374.5-liter system volume.
  • Financing Available: Qualified purchasers may finance from $253.48/month. Contact Cannafull Spectrum Solutions for current financing terms.

System Integration

  • Electrical: The V-SYSTEM Vortex Water Pump requires a dedicated 120V grounded circuit rated for continuous 250W draw. Do not share the circuit with high-inrush lighting or HVAC equipment without load calculation review by a licensed electrician.
  • Water Supply: The system requires access to a potable or RO water source for initial fill and reservoir top-off. The float valve automates top-off between manual service intervals; confirm supply line pressure is compatible with the float valve inlet specification.
  • Drainage: Total-drainage bases on each V-POT require floor-level drain access or a collection vessel for full system flush and reservoir change operations. Plan drainage routing before finalizing layout variant selection.
  • Nutrient Dosing: The 374.5-liter total fluid volume requires nutrient solution preparation at scale. Operators should confirm mixing vessel capacity and EC/pH monitoring equipment are in place before first fill.
  • Environmental Controls: Reservoir temperature directly affects dissolved oxygen levels in RDWC systems. Facilities without active reservoir chilling should monitor solution temperature and account for ambient heat load from the pump (250W continuous) when sizing environmental controls.

Facility Integration Data

The following ROI reference table is provided to assist procurement and operations teams in evaluating multi-unit deployment economics for the Alien V-SYSTEM 6 Pot Kit at $2,808.38 per unit.

Fleet Deployment Cost Reference

Fleet Size Total Units Total Plant Sites Total Fluid Volume (L) Aggregate Pump Draw (W) Capital Outlay (USD)
Entry 10 60 3,745 L 2,500W $28,083.80
Mid-Scale 20 120 7,490 L 5,000W $56,167.60
Production Scale 50 300 18,725 L 12,500W $140,419.00

Capital outlay figures are based on single-unit MSRP of $2,808.38. Volume pricing may be available for multi-unit orders — contact Cannafull Spectrum Solutions for fleet procurement terms. Pump draw figures assume one pump per unit at 250W continuous. Electrical infrastructure must be engineered to support aggregate load by a licensed electrician.


Operator Field Notes

  • Layout selection is a pre-order decision: All four variants (MIH, MOL, MOR, MSP) share identical system specifications. The only variable is assembled footprint. Measure your space against the published dimensions before selecting a variant — returns of non-defective items are subject to restocking fees.
  • Venturi oxygenation is flow-dependent: Oxygen saturation through the Venturi injectors is driven by pump pressure and flow rate. Any restriction in the distribution lines — kinked tubing, partially closed fittings, or particulate buildup at the filter — will reduce oxygenation performance. Inspect the integrated filtration at each reservoir service interval.
  • Float valve top-off is not a substitute for reservoir management: The float valve maintains fluid level between service intervals, but does not correct nutrient concentration drift. EC and pH must be monitored and adjusted manually on a scheduled basis regardless of auto top-off operation.
  • T304 stainless clamps require torque verification after first fill: Thermal expansion during initial operation can relax clamp tension. Inspect and re-torque all T304 stainless clamps after the first 24–48 hours of recirculating operation.
  • Pump heat load is real: The 250W pump operates continuously and contributes to ambient and reservoir temperature. In warm environments, monitor reservoir temperature closely and consider a reservoir chiller if solution temperature consistently exceeds 68°F (20°C).
  • Push-fit connections are tool-free but not force-free: Push-fit feed connections require firm, full-depth insertion to seat the internal O-ring correctly. A partial-depth connection will weep under recirculating pressure. Verify each connection is fully seated before initiating pump operation.

Operator FAQ

Q: What is the difference between the four layout variants (MIH, MOL, MOR, MSP)?

A: All four variants are mechanically identical — same pump, same fluid volume, same V-POT capacity, same price. The only difference is the assembled footprint, which is determined by where the header and pump are positioned relative to the pot rows. MIH is the most compact internal configuration (76⅜" x 56¾"). MOL and MOR offset the header and pump to the left or right respectively for external placement (95½" x 65½" and 93⅞" x 65½"). MSP provides a split configuration optimized for space-constrained internal routing (92⅜" x 52¾"). Select the variant whose assembled dimensions fit your cultivation space before ordering.

Q: Why does the V-SYSTEM not require an air pump?

A: Oxygen is introduced into the nutrient solution passively through Venturi injectors integrated into the recirculating flow path. As solution passes through the Venturi geometry at high velocity — driven by the 11,700 L/h Vortex pump — atmospheric oxygen is drawn into the fluid stream without any secondary pump or airstones. This eliminates an entire subsystem, reduces electrical draw, and removes a common failure point from the irrigation infrastructure.

Q: What electrical circuit does the V-SYSTEM pump require?

A: The V-SYSTEM Vortex Water Pump operates at 120V and draws 250W continuously. It requires a dedicated, properly grounded 120V circuit. Do not share this circuit with high-inrush equipment such as HID lighting ballasts or HVAC compressors without a load calculation performed by a licensed electrician. Confirm circuit capacity before installation.

Q: Does the float valve eliminate the need for manual reservoir monitoring?

A: No. The float valve automates fluid level top-off between service intervals, maintaining total system volume as water is transpired by plants. It does not monitor or correct nutrient concentration (EC) or pH. As plain water is added to replace transpired volume, nutrient concentration will drift upward over time. EC and pH must be measured and adjusted on a scheduled basis by the operator regardless of float valve operation.

Q: What is the total fluid volume of the system and how is it distributed?

A: The total system fluid volume is 374.5 liters (98.9 gallons) across the full kit. Each of the six V-POTs holds 58 liters (15 gallons). The remaining volume is held in the central reservoir and distribution plumbing. This volume-to-plant ratio provides meaningful thermal buffering and nutrient concentration stability compared to smaller-volume systems, reducing the frequency and magnitude of EC and pH swings between service intervals.

Q: What warranty applies to the Alien V-SYSTEM 6 Pot Kit?

A: Warranty terms for SKU BD100-0206 are not specified in currently available manufacturer source data. Cannafull Spectrum Solutions recommends contacting us directly before purchase to confirm current warranty coverage, terms, and claim procedures directly with the manufacturer. Do not assume a warranty period applies without written confirmation.


Shipping & Logistics

  • Free Shipping: Free shipping is available to the contiguous 48 United States. Shipments are not available to Alaska, Hawaii, or U.S. territories through this listing.
  • Freight & Handling: The V-SYSTEM 6 Pot Kit ships as a multi-component system. Confirm a receiving dock or ground-level delivery access is available at the destination facility. Weight data is not specified in source; contact Cannafull Spectrum Solutions for freight class and pallet configuration details prior to scheduling delivery.
  • Returns: Returns of defective units are handled per manufacturer warranty procedures. Non-defective returns must be initiated within the return window specified in the Cannafull Spectrum Solutions Return Policy. Units must be unassembled and in original packaging to qualify for return consideration.
  • Restocking Fee: Returns of non-defective items are subject to a restocking fee of up to 25% per our Return Policy. Review full terms at cannafullspec.com/pages/return-policy before ordering.

Questions about shipping, freight routing, or multi-unit delivery coordination? Contact Cannafull Spectrum Solutions directly before placing your order.


What's in the Box

The Alien V-SYSTEM 6 Pot 2 Row Kit includes 24 component items per manufacturer specification. Confirmed system-level components include:

  • 6x V-POT vessels (58 L / 15 gal each)
  • V-SYSTEM Vortex Water Pump (JET-STREAM® Vortex™, 250W / 120V / 11,700 L/h)
  • Central reservoir (included in 374.5 L total fluid volume)
  • 5" spiral tubing (distribution network)
  • 5" Dual-Flow™ fittings
  • Venturi injectors (integrated oxygenation)
  • Integrated filtration assembly
  • T304 stainless clamps
  • Push-fit feed connections
  • Float valve for automatic reservoir top-off
  • Water fill line
  • Total-drainage bases
  • Inspection covers

The complete 24-item component manifest is available from Cannafull Spectrum Solutions upon request. Component list is subject to change by the manufacturer without notice. Verify included items against the packing list upon receipt before discarding packaging. Cannafull Spectrum Solutions is not responsible for missing components not reported within the manufacturer's specified claim window.


Regional Compliance & Deployment Notes

  • Shipping Jurisdiction: Cannafull Spectrum Solutions ships the Alien V-SYSTEM 6 Pot Kit within the contiguous 48 United States only. Orders cannot be fulfilled to addresses outside this jurisdiction through this listing.
  • Electrical Compliance: The V-SYSTEM Vortex Water Pump operates at 120V / 250W. All electrical installations must comply with the National Electrical Code (NEC) and applicable state and local electrical codes. A licensed electrician must verify circuit capacity and grounding before pump installation.
  • Plumbing & Drainage: Recirculating irrigation systems may be subject to local plumbing code requirements depending on facility classification and jurisdiction. Operators in licensed cultivation facilities should confirm compliance with their facility engineer or local authority having jurisdiction (AHJ) before installation.
  • Water Use Regulations: Facilities operating in water-restricted jurisdictions should confirm that recirculating RDWC systems comply with applicable water use and discharge regulations. Total-drainage operations during reservoir changes may require compliant disposal or recapture procedures.
  • Licensed Facility Compliance: This system is deployed in licensed cultivation facilities across the United States. Operators are solely responsible for ensuring that their cultivation infrastructure complies with all applicable state and local licensing, zoning, and operational regulations. Cannafull Spectrum Solutions makes no representations regarding regulatory compliance for any specific jurisdiction.

Compliance requirements vary by state, county, and facility classification. The information provided here is for general reference only and does not constitute legal, engineering, or regulatory advice. Consult a licensed engineer and your state regulatory authority before finalizing installation plans. Cannafull Spectrum Solutions assumes no liability for installations that do not comply with applicable local, state, or federal regulations.

Route Package Protection

在 CannaFull Spectrum Solutions,我们明白在运输过程中安心是至关重要的。这就是为什么我们自豪地为您的所有在线订单提供全面的运输保护和跟踪解决方案 Route!

Route:您的一体化运输中心

Route 与您的 CannaFull Spectrum Solutions 购物体验无缝集成,让您完全掌控配送过程,安心无忧。以下是 Route 提供的功能:

  • 自动包裹保护:在 CannaFull Spectrum Solutions 上下的每个订单都会自动附带 Route 的基本保护计划,保护您的购买免遭包裹丢失、被盗或损坏。
  • 增强型跟踪: Route 超越了基本跟踪信息。获取实时更新、预计交付时间以及有关潜在延误或问题的主动警报。
  • 轻松的索赔管理:如果您的包裹遇到问题,Route 可简化索赔流程。直接通过 Route 应用提出索赔,即可快速高效地获得解决方案。
  • 价格匹配保证: Route 可确保您获得最优惠的价格。如果您在一定时间内(通常为 48 小时)发现同一商品的广告价格更低,Route 将退还差价。
  • 丢失邮件更换: Route 提供额外的安全保障。如果您的包裹被标记为已送达但您从未收到,Route 可能会更换它,具体取决于具体物品和承保选项。

使用大麻全光谱解决方案路线的好处:

  • 放心购物:知道您购买的商品不会丢失、被盗或损坏,您就可以完全放心购物。
  • 轻松跟踪:利用 Route 的实时跟踪和主动通知随时了解每一步情况。
  • 轻松索赔: Route 简化了索赔流程,在您遇到任何与交付相关的问题时,可为您节省时间并避免烦恼。
  • 每次购买都增加价值: Route 会自动为您的 [您的商店名称] 订单提供基本保护和有价值的跟踪功能,无需支付额外费用。

如何开始路线:

使用 Route 购买 CannaFull Spectrum Solutions 简单又方便:

  1. 完成您的订单:当您在 CannaFull Spectrum Solutions 结账时,您将看到激活 Route 对您的订单的保护的选项(通常是预先选择的)。
  2. 下载路线应用程序:为了获得更加无缝的体验,请下载适用于 iOS 和 Android 的免费路线应用程序。
  3. 追踪您的包裹:登录路线应用程序或查看您的电子邮件以获取追踪更新并管理您的受保护货件。

Route:您的无忧运输合作伙伴

CannaFull Spectrum Solutions 致力于通过每次购买提供 Route 服务,为您提供无压力的购物体验。Route 让您可以放心购物,因为您知道您的包裹受到保护,并且每一步都可以轻松跟踪。

常见问题:

  • Route 是免费的吗? CannaFull Spectrum Solutions 的每笔订单都会自动包含基本 Route 保护。Route 还提供具有附加功能和覆盖范围的可选高级计划。
  • 如何向 Route 提出索赔?可通过 Route 应用程序或网站轻松提出索赔。
  • 如果我的包裹丢失了怎么办?根据具体情况和您选择的保险计划,Route 可能会赔偿您或更换丢失的物品。

放心购物,轻松追踪!选择 CannaFull Spectrum Solutions,在下次在线购物时体验 Route 的强大功能。

Shiping, Cancelations & Returns

订单处理:我们努力在 1-2 个工作日内处理所有订单。
运费和方式:我们提供多种运输方式以满足您的需求和预算。预计交货时间将在结账时显示,并可能因您选择的方式和位置而异。
  • 标准运费(预计 3-5 个工作日内送达):X 美元(Y 美元以上订单免费)
  • 加急运输(预计 1-2 个工作日内送达):$Z

国际运输(如适用):我们目前提供/不提供国际运输。(如果您提供,请注明费率和预计交货时间)。

追踪和路线保护:订单发货后,您将通过电子邮件收到带有追踪号的通知。我们还与 Route 合作,在结账时为所有订单提供额外的运输保护(包裹丢失、被盗或损坏),只需支付少量费用。

请注意:由于代发货的特性,送货时间可能比其他商店宣传的稍长。我们努力提供尽可能准确的估算,但可能会出现不可预见的情况。

取消政策

我们理解计划可能会发生变化,因此您可以在下单后 24 小时内取消订单并获得全额退款。如果您的订单已转发给我们的履行合作伙伴,我们将尽力满足您的取消请求,但可能会收取全额取消费或商店信用额。

退货政策

我们希望您对所购商品完全满意。如果您出于任何原因不满意,您可以在购买之日起 30 天内退回符合条件的商品。

符合条件的商品:大多数全新、未使用、未开封且带原包装的商品均符合退货条件。例外情况可能包括(如适用,请列出任何例外情况,例如最终销售商品或易腐烂商品)。

退货条件:要获得全额退款,退回的商品必须是未使用状态,且所有原始标签和包装完好无损。

退货运费:如果退货是由于我们的错误(例如,寄送了错误的商品)造成的,我们将承担退货运费。否则,您将承担退货运费。但是,您可以使用 Route 的保护计划(如果购买)来补偿丢失、被盗或损坏包裹的退货运费。

退款流程:收到您退回的商品并核实其状况后,我们将在 X 个工作日内处理您的退款。退款将以您原来的付款方式或商店信用额度发放,具体取决于您的偏好。

通过在我们这里购物,您同意本运输、取消和退货政策中概述的条款。

Warranty

在 CannaFull Spectrum Solutions,我们希望您对购买的产品充满信心。我们提供的许多 LED 生长灯都附带制造商保修,确保您的投资得到保护。

了解您的保修:

  • 具体保修条款和条件将根据您购买的个别产品而有所不同。
  • 我们强烈建议您在收到产品时查看随附的制造商保修信息。
  • 该信息通常详细说明保修期、保险范围和索赔流程。

帮助中心:

虽然保修由制造商直接处理,但我们理解处理保修索赔有时会令人困惑。在 CannaFull Spectrum Solutions,我们在整个过程中为您提供支持:

  • 轻松访问保修信息:我们努力在每个产品页面上提供清晰简明的保修信息。这通常包括可下载的保修文件或制造商保修网站的链接。
  • 专属客户支持:如果您对产品保修有任何疑问或需要帮助提出索赔,请随时联系我们友好的客户支持团队。我们将很乐意指导您完成整个流程,并帮助您从制造商处获得应有的支持。

我们能做什么:

虽然我们不能直接处理保修索赔,但我们可以通过以下几种方式为您提供帮助:

  • 帮助找到您的特定产品的相关保修信息。
  • 提供制造商保修部门的联系方式。
  • 提供有关完成和提交保修索赔的指导。
  • 充当您和制造商之间的联络人,让您随时了解整个过程。

我们对您的承诺:

CannaFull Spectrum Solutions 致力于提供积极的客户体验。我们希望您对购买的产品感到满意,这包括确保您的保修索赔得到迅速有效的处理。

Payment & Security

Payment methods

  • American Express
  • Diners Club
  • Discover
  • Google Pay
  • JCB
  • Mastercard
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Buy now pay later with