AC Infinity CLOUDLINE PRO T6 | 带温度湿度 VPD 控制器的静音直列管道风扇系统 | 6 英寸
AC Infinity CLOUDLINE PRO T6 | 带温度湿度 VPD 控制器的静音直列管道风扇系统 | 6 英寸 已缺货,一旦有货将立即发货。
Unlock Trade Pricing
Join our commercial tier for bulk pricing and inventory alerts.
AC Infinity CLOUDLINE PRO T6 | 带温度湿度 VPD 控制器的静音直列管道风扇系统 | 6 英寸 已缺货,一旦有货将立即发货。
描述
描述
AC Infinity AI-CLT6: 6-Inch Mixed-Flow Inline Fan with Smart Controller
The AC Infinity CLOUDLINE T Series AI-CLT6 is a 70W, 6-inch mixed-flow inline fan engineered for facility directors managing sealed cultivation environments who require automated, programmable atmospheric control with sustained static pressure performance.
- Outcome: Stable, automated airflow management with dynamic climate and time-based programming — eliminating manual intervention and environmental drift.
- Replaces: Fixed-speed inline fans, passive exhaust configurations, and manually adjusted ventilation systems that cannot respond to real-time environmental conditions.
- Environment: Sealed commercial cultivation rooms, odor exhaust runs, and high-static-pressure duct configurations requiring quiet, energy-efficient operation.
FACTORY-AUTHORIZED DEALER — CANNAFULL SPECTRUM SOLUTIONS
Deployed in licensed commercial facilities across the United States.
Key Specs: 70W Max | 32 dBA | 503 Pa Static Pressure | 67,000-Hour L10 Life | 6-Inch Duct | ETL & CE Certified | 2-Year Warranty
Kill Variance. Print Yield.
Every sealed cultivation room running on fixed-speed ventilation is bleeding yield through a failure mode that never shows up on a single harvest report — it accumulates silently across every cycle. When airflow cannot respond to thermal load, CO2 stratification, or humidity spikes in real time, the environment drifts. That drift is not a single catastrophic event; it is a slow, compounding tax on canopy uniformity, transpiration efficiency, and pathogen suppression. Legacy inline fans with no dynamic control architecture have no mechanism to correct course. They run at one speed, regardless of what the room demands, and the operator absorbs the cost in reduced consistency, elevated disease pressure, and the labor overhead of manual adjustment cycles that should not exist in a production facility.
After deploying a programmable, dynamically controlled ventilation platform, the facility operates on a different logic entirely. Temperature and humidity setpoints are maintained automatically across the full photoperiod. Odor exhaust runs hold consistent negative pressure without operator intervention. Duct runs under high static load — long runs, multiple bends, carbon filter resistance — maintain target airflow because the motor has the headroom and the intelligence to compensate. The facility director's attention shifts from reactive environmental firefighting to proactive production planning. That is the operational state this equipment is designed to create.
The mechanism behind that outcome is a PWM-controlled EC motor operating inside a mixed-flow impeller design — a configuration that combines the high static pressure capability of an axial fan with the efficiency profile of a centrifugal unit. The integrated smart controller supports dynamic climate-based programming and time-based scheduling, allowing the fan to respond to sensor inputs or operate on a defined duty cycle without manual override. Maximum power draw is 70W at full speed, noise output is rated at 32 dBA, and the unit sustains up to 503 Pa of static pressure — sufficient for carbon filter and extended duct configurations common in sealed commercial rooms. The motor carries an L10 life expectancy of 67,000 hours, and the unit is ETL, CE, RoHS, SAA, and IC certified for commercial installation. In practical terms, the AI-CLT6 delivers automated, sensor-responsive airflow through a 6-inch duct at a maximum draw of 70W, sustaining 503 Pa of static pressure at 32 dBA across the operational life of the motor.
Where This Belongs (and Doesn't)
This unit requires a 6-inch duct configuration and a compatible electrical circuit rated for the installation. Verify duct diameter, static pressure load, and circuit capacity before deployment. HVAC sizing for sealed rooms must account for total heat load independent of this unit's power draw.
Engineered For
- Sealed commercial cultivation rooms requiring automated atmospheric control
- 6-inch duct exhaust and intake runs with carbon filter resistance
- High-static-pressure applications: long duct runs, multiple bends, filter-loaded configurations
- Facilities integrating into the AC Infinity UIS ecosystem for centralized controller management
- Odor exhaust systems requiring consistent negative pressure maintenance
- Operators requiring ETL-certified ventilation equipment for AHJ compliance documentation
Not Recommended For
- Duct configurations other than 6-inch diameter without appropriate reducers
- Installations requiring duct sizes of 4, 8, 10, or 12 inches — select the corresponding CLOUDLINE T Series SKU
- Environments where noise levels above 32 dBA are a disqualifying factor at maximum speed
- Facilities that do not require programmable or sensor-responsive airflow control and are seeking a fixed-speed solution only
Infrastructure Note: The AI-CLT6 operates on 100–240V AC at 50/60Hz, making it compatible with both standard U.S. facility circuits and international voltage configurations. Confirm duct collar compatibility and controller wiring clearances before installation in existing duct runs.
How It Works
The AI-CLT6 is built around a mixed-flow impeller design — a geometry that draws air axially and discharges it with a radial component, producing the static pressure performance of a centrifugal fan without the bulk or noise penalty typically associated with that form factor. This design is what allows the unit to sustain 503 Pa of static pressure through loaded duct runs while maintaining a 32 dBA acoustic profile at the rated operating point. The impeller is driven by a PWM-controlled EC (electronically commutated) motor, which replaces the fixed-speed AC induction motor found in standard inline fans. EC motor architecture allows the controller to modulate fan speed in precise increments rather than switching between fixed speed taps, which is the foundational requirement for dynamic climate response.
The integrated smart controller is the operational interface between the motor and the facility environment. It supports two primary programming modes: dynamic climate-based programming, which adjusts fan speed in response to temperature and humidity sensor inputs, and time-based programming, which runs the fan on a defined duty cycle independent of sensor feedback. Both modes can be configured without external controllers, though the unit is designed for integration into the AC Infinity UIS (Universal Intelligence System) ecosystem, enabling centralized management across multiple units from a single Cortex controller interface. Maximum power draw at full speed is 70W on a 100–240V AC, 50/60Hz supply. The L10 life expectancy of the EC motor is rated at 67,000 hours — a figure that reflects the point at which 10% of units in a population are expected to have failed, making it a conservative engineering benchmark rather than a marketing average. In practical terms, the AI-CLT6 delivers PWM-modulated, sensor-responsive airflow through a 6-inch duct at 70W maximum draw, sustaining 503 Pa static pressure at 32 dBA with a 67,000-hour motor life rating.
Commercial Assurance
- Warranty: 2-year product warranty per manufacturer terms. Warranty claims processed through Cannafull Spectrum Solutions — contact (888) 378-0017 or sales@cannafullspec.com to initiate.
- 30-Day Return: Units in original, uninstalled condition are eligible for return within 30 days of delivery with a Return Authorization (RA) number issued by Cannafull Spectrum Solutions.
- Motor Lifespan: L10 life expectancy of 67,000 hours per manufacturer specification for the PWM-controlled EC motor.
- Factory-Authorized Dealer: Cannafull Spectrum Solutions is a factory-authorized AC Infinity dealer. All units are sourced through authorized distribution channels and carry full manufacturer warranty eligibility.
System Integration
To operate this platform at peak efficiency, verify your ecosystem matches these requirements:
- Controller Compatibility: The AI-CLT6 integrates natively with the AC Infinity UIS ecosystem. For centralized multi-unit management, pair with a compatible AC Infinity Cortex controller. Standalone operation using the onboard smart controller requires no additional hardware.
- Duct Configuration: Confirm 6-inch duct collar diameter at both inlet and outlet connection points. Use appropriate reducers or transitions if integrating into existing duct runs of differing diameter.
- Electrical Supply: Unit accepts 100–240V AC at 50/60Hz. Confirm circuit capacity for 70W maximum draw. For multi-unit installations, calculate aggregate draw and size circuits accordingly — do not share circuits with high-inrush equipment without verified breaker capacity.
- HVAC Capacity: The AI-CLT6 manages airflow but does not replace room-level HVAC sizing. Total sensible and latent heat load for the cultivation space must be calculated independently. Ventilation airflow rates should be coordinated with your HVAC engineer to ensure negative pressure targets do not conflict with makeup air supply.
- Sensor Integration: For dynamic climate-based programming, compatible temperature and humidity sensors must be positioned to provide accurate room-representative readings. Sensor placement at canopy level is recommended for cultivation environment applications.
Facility Integration Data
Use the figures below to model ventilation infrastructure costs and replacement cycles across fleet deployments of the AI-CLT6 in licensed commercial facilities.
ROI Reference — Annual Fleet Cost Model (AI-CLT6 at $149.00 MAP)
Electrical / Thermal
| SKU | W (W) | BTU/hr | Input V |
|---|---|---|---|
| AI-CLT6 | 70 | 239 | 100-240V AC |
BTU/hr shown is computed from wattage using 3.412 BTU/hr per watt. Verify against manufacturer specifications.
Power draw calculated at 70W maximum continuous. Actual draw will be lower under dynamic speed control. kWh cost not included — apply your facility's utility rate. L10 life figure is a motor population benchmark, not a guaranteed individual unit lifespan.
Why This Over a Standard Inline Fan
- Fixed-speed AC induction motors run at full draw regardless of room demand, wasting energy and creating noise at all operating conditions: the AI-CLT6's PWM-controlled EC motor modulates speed in precise increments, reducing power consumption and acoustic output at partial load — rated at 32 dBA and 70W maximum.
- Standard inline fans with no controller memory lose all programmed settings on power interruption, requiring manual reconfiguration after every outage: the AI-CLT6's smart controller retains dynamic climate and time-based programming across power cycles, maintaining automated atmospheric control without operator intervention.
- Commodity inline fans with sleeve or ball-bearing motors in standard configurations carry L10 life ratings well below 50,000 hours under continuous load: the AI-CLT6's EC motor is rated to an L10 life expectancy of 67,000 hours, reducing replacement frequency and unplanned downtime in continuous-operation cultivation environments.
Operator Field Note
- Electrical Draw: Maximum power draw is 70W at full speed on a 100–240V AC, 50/60Hz supply. At 120V, this represents approximately 0.58A at full load. At 240V, approximately 0.29A. Confirm circuit capacity before installation, particularly in multi-unit configurations sharing a single branch circuit.
- Static Pressure Ceiling: The unit is rated to 503 Pa maximum static pressure. For duct runs with carbon filter resistance, calculate total system static pressure including filter drop, duct friction, and fitting losses before selecting this unit. Exceeding the static pressure rating will result in reduced airflow, not fan failure, but will degrade environmental control performance.
- Acoustic Profile: The 32 dBA noise rating applies at the rated operating point. Actual noise output will vary with speed setting and duct configuration. Turbulence at duct transitions and filter faces can add acoustic energy independent of the fan's rated output.
- Motor Life Benchmark: The 67,000-hour L10 life figure is a population-level engineering benchmark — it represents the point at which 10% of motors in a tested population are expected to have reached end of life. It is not a guaranteed individual unit lifespan. Plan preventive replacement schedules accordingly for critical airflow paths.
- Certification Scope: ETL, CE, RoHS, SAA, and IC certifications apply to the whole product as shipped. Modifications to the unit, duct connections, or controller wiring outside manufacturer specifications may void certification status and warranty coverage.
Operator FAQ
Q: What circuit amperage is required to run the AI-CLT6, and can multiple units share a single branch circuit?
A: The AI-CLT6 draws a maximum of 70W. At 120V, this is approximately 0.58A at full load; at 240V, approximately 0.29A. A standard 15A or 20A branch circuit can support multiple units simultaneously at full draw — for example, a 20A/120V circuit has approximately 16A of usable capacity (80% NEC derate), which can support up to 27 units at full load. However, always account for other loads on the same circuit and verify with a licensed electrician before finalizing your circuit layout. Dynamic speed control will reduce actual draw below the 70W maximum during normal operation.
Q: What controller modes does the AI-CLT6 support, and does it require an external controller to operate?
A: The AI-CLT6 includes an integrated smart controller that supports two primary modes: dynamic climate-based programming, which adjusts fan speed automatically in response to temperature and humidity sensor inputs, and time-based programming, which runs the fan on a defined duty cycle. No external controller is required for standalone operation. For centralized management of multiple units across a facility, the AI-CLT6 is designed for integration into the AC Infinity UIS (Universal Intelligence System) ecosystem and is compatible with AC Infinity Cortex controllers. Controller memory is retained across power cycles.
Q: What is the recommended mounting orientation and installation position for the AI-CLT6 in a commercial duct run?
A: The AI-CLT6 is designed for inline duct installation and can be mounted in horizontal or vertical orientations depending on your duct routing. Secure the unit using appropriate duct hangers or brackets rated for the unit's weight — confirm the unit's actual weight upon receipt, as this specification was not available in manufacturer source data at time of publication. Ensure adequate clearance around the controller housing for heat dissipation and access. Position the unit upstream of carbon filters where possible to reduce particulate ingestion into the motor housing. Always follow local mechanical code requirements for inline fan installation in commercial environments.
Q: What duct size does the AI-CLT6 fit, and what is the maximum static pressure it can sustain?
A: The AI-CLT6 is a 6-inch duct diameter unit. It is not compatible with 4, 8, 10, or 12-inch duct configurations without reducers or transitions — select the corresponding CLOUDLINE T Series SKU for other duct sizes. The unit sustains a maximum static pressure of 503 Pa, which is sufficient for most commercial carbon filter and extended duct run configurations. For installations with high resistance loads, calculate total system static pressure including filter drop, duct friction losses, and fitting resistance to confirm the unit's static pressure rating is not exceeded.
Q: What is the motor lifespan, and what maintenance does the AI-CLT6 require during its operational life?
A: The AI-CLT6's PWM-controlled EC motor carries an L10 life expectancy of 67,000 hours. This is a population-level engineering benchmark representing the point at which 10% of motors in a tested population are expected to have reached end of life under rated conditions — at continuous operation, this projects to approximately 7.6 years. The EC motor design eliminates brush wear as a maintenance variable. Routine maintenance should include periodic inspection of the duct connections for air leakage, verification that the controller display and sensor inputs are reading accurately, and confirmation that the intake and exhaust faces are free of debris accumulation. No internal lubrication or brush replacement is required.
Q: What warranty does the AI-CLT6 carry, and how do I initiate a warranty claim through Cannafull Spectrum Solutions?
A: The AI-CLT6 carries a 2-year product warranty per AC Infinity manufacturer terms. To initiate a warranty claim, contact Cannafull Spectrum Solutions directly at (888) 378-0017 or sales@cannafullspec.com. A Return Authorization (RA) number is required before any unit is returned for warranty evaluation. Do not ship units without an RA number — unauthorized returns cannot be processed. Cannafull Spectrum Solutions is a factory-authorized AC Infinity dealer, and all units sold through our channel carry full manufacturer warranty eligibility. Retain your purchase documentation as proof of purchase for warranty claim processing.
Shipping & Logistics
- Origin: Ships from Cannafull Spectrum Solutions' authorized distribution point within the contiguous 48 United States. This product is not available for shipment outside the contiguous U.S.
- Processing: Orders are processed within 1–2 business days of confirmed payment. Expedited processing is not guaranteed — contact (888) 378-0017 for time-sensitive deployment inquiries.
- Damage: Inspect all shipments within 48 hours of delivery. Document any visible damage with photographs before opening packaging. Report damage to Cannafull Spectrum Solutions within 48 hours of receipt at (888) 378-0017 or sales@cannafullspec.com. Claims submitted after 48 hours may not be eligible for carrier resolution.
- Returns: Units in original, uninstalled condition are eligible for return within 30 days of delivery. A Return Authorization (RA) number issued by Cannafull Spectrum Solutions is required before return shipment. Contact (888) 378-0017 or sales@cannafullspec.com to initiate.
- Restocking Fee: Returns of non-defective items are subject to a restocking fee of up to 25% per our Return Policy. Review full terms at cannafullspec.com/pages/return-policy before ordering.
Questions? (888) 378-0017 or sales@cannafullspec.com
What's in the Box
- AC Infinity CLOUDLINE T Series AI-CLT6 6-inch mixed-flow inline fan with integrated smart controller
- Controller unit (integrated — no separate controller component required for standalone operation)
- Documentation package (user manual and certification documentation)
Note: Box contents are based on available manufacturer data. Verify complete contents upon receipt. Contact Cannafull Spectrum Solutions at (888) 378-0017 if any components are missing or damaged.
Regional Compliance & Deployment Notes
- All 50 U.S. States: Available for commercial deployment across all 50 U.S. states where cultivation is legally permitted. Operators are responsible for verifying that ventilation installations comply with applicable state and local regulations.
- California (CA): California energy efficiency (Title 20) regulations apply to commercial ventilation equipment. Verify compliance with your local AHJ before permanent installation.
- Colorado (CO): Licensed cultivation facilities should verify that ventilation equipment meets MED facility construction and equipment standards. Electrical installations require licensed contractor sign-off per state code.
- Michigan (MI): MMFLA and MRTMA licensed facilities should confirm that inline fan installations meet LARA facility standards.
- Nevada (NV): CCB-licensed cultivation facilities should verify NEC compliance for ventilation circuit installations.
- Oklahoma (OK): OMMA-licensed facilities should verify local fire marshal and building code requirements for enclosed cultivation environment ventilation.
Commonly deployed in sealed commercial cultivation facilities across the United States. Installation, HVAC sizing, and electrical requirements vary by jurisdiction; always verify with local code.
规格
规格
-
Product Category
Route Package Protection
Route Package Protection
在 CannaFull Spectrum Solutions,我们明白在运输过程中安心是至关重要的。这就是为什么我们自豪地为您的所有在线订单提供全面的运输保护和跟踪解决方案 Route!
Route:您的一体化运输中心
Route 与您的 CannaFull Spectrum Solutions 购物体验无缝集成,让您完全掌控配送过程,安心无忧。以下是 Route 提供的功能:
- 自动包裹保护:在 CannaFull Spectrum Solutions 上下的每个订单都会自动附带 Route 的基本保护计划,保护您的购买免遭包裹丢失、被盗或损坏。
- 增强型跟踪: Route 超越了基本跟踪信息。获取实时更新、预计交付时间以及有关潜在延误或问题的主动警报。
- 轻松的索赔管理:如果您的包裹遇到问题,Route 可简化索赔流程。直接通过 Route 应用提出索赔,即可快速高效地获得解决方案。
- 价格匹配保证: Route 可确保您获得最优惠的价格。如果您在一定时间内(通常为 48 小时)发现同一商品的广告价格更低,Route 将退还差价。
- 丢失邮件更换: Route 提供额外的安全保障。如果您的包裹被标记为已送达但您从未收到,Route 可能会更换它,具体取决于具体物品和承保选项。
使用大麻全光谱解决方案路线的好处:
- 放心购物:知道您购买的商品不会丢失、被盗或损坏,您就可以完全放心购物。
- 轻松跟踪:利用 Route 的实时跟踪和主动通知随时了解每一步情况。
- 轻松索赔: Route 简化了索赔流程,在您遇到任何与交付相关的问题时,可为您节省时间并避免烦恼。
- 每次购买都增加价值: Route 会自动为您的 [您的商店名称] 订单提供基本保护和有价值的跟踪功能,无需支付额外费用。
如何开始路线:
使用 Route 购买 CannaFull Spectrum Solutions 简单又方便:
- 完成您的订单:当您在 CannaFull Spectrum Solutions 结账时,您将看到激活 Route 对您的订单的保护的选项(通常是预先选择的)。
- 下载路线应用程序:为了获得更加无缝的体验,请下载适用于 iOS 和 Android 的免费路线应用程序。
- 追踪您的包裹:登录路线应用程序或查看您的电子邮件以获取追踪更新并管理您的受保护货件。
Route:您的无忧运输合作伙伴
CannaFull Spectrum Solutions 致力于通过每次购买提供 Route 服务,为您提供无压力的购物体验。Route 让您可以放心购物,因为您知道您的包裹受到保护,并且每一步都可以轻松跟踪。
常见问题:
- Route 是免费的吗? CannaFull Spectrum Solutions 的每笔订单都会自动包含基本 Route 保护。Route 还提供具有附加功能和覆盖范围的可选高级计划。
- 如何向 Route 提出索赔?可通过 Route 应用程序或网站轻松提出索赔。
- 如果我的包裹丢失了怎么办?根据具体情况和您选择的保险计划,Route 可能会赔偿您或更换丢失的物品。
放心购物,轻松追踪!选择 CannaFull Spectrum Solutions,在下次在线购物时体验 Route 的强大功能。
Shiping, Cancelations & Returns
Shiping, Cancelations & Returns
- 标准运费(预计 3-5 个工作日内送达):X 美元(Y 美元以上订单免费)
- 加急运输(预计 1-2 个工作日内送达):$Z
国际运输(如适用):我们目前提供/不提供国际运输。(如果您提供,请注明费率和预计交货时间)。
追踪和路线保护:订单发货后,您将通过电子邮件收到带有追踪号的通知。我们还与 Route 合作,在结账时为所有订单提供额外的运输保护(包裹丢失、被盗或损坏),只需支付少量费用。
请注意:由于代发货的特性,送货时间可能比其他商店宣传的稍长。我们努力提供尽可能准确的估算,但可能会出现不可预见的情况。
取消政策
我们理解计划可能会发生变化,因此您可以在下单后 24 小时内取消订单并获得全额退款。如果您的订单已转发给我们的履行合作伙伴,我们将尽力满足您的取消请求,但可能会收取全额取消费或商店信用额。
退货政策
我们希望您对所购商品完全满意。如果您出于任何原因不满意,您可以在购买之日起 30 天内退回符合条件的商品。
符合条件的商品:大多数全新、未使用、未开封且带原包装的商品均符合退货条件。例外情况可能包括(如适用,请列出任何例外情况,例如最终销售商品或易腐烂商品)。
退货条件:要获得全额退款,退回的商品必须是未使用状态,且所有原始标签和包装完好无损。
退货运费:如果退货是由于我们的错误(例如,寄送了错误的商品)造成的,我们将承担退货运费。否则,您将承担退货运费。但是,您可以使用 Route 的保护计划(如果购买)来补偿丢失、被盗或损坏包裹的退货运费。
退款流程:收到您退回的商品并核实其状况后,我们将在 X 个工作日内处理您的退款。退款将以您原来的付款方式或商店信用额度发放,具体取决于您的偏好。
通过在我们这里购物,您同意本运输、取消和退货政策中概述的条款。
Warranty
Warranty
在 CannaFull Spectrum Solutions,我们希望您对购买的产品充满信心。我们提供的许多 LED 生长灯都附带制造商保修,确保您的投资得到保护。
了解您的保修:
- 具体保修条款和条件将根据您购买的个别产品而有所不同。
- 我们强烈建议您在收到产品时查看随附的制造商保修信息。
- 该信息通常详细说明保修期、保险范围和索赔流程。
帮助中心:
虽然保修由制造商直接处理,但我们理解处理保修索赔有时会令人困惑。在 CannaFull Spectrum Solutions,我们在整个过程中为您提供支持:
- 轻松访问保修信息:我们努力在每个产品页面上提供清晰简明的保修信息。这通常包括可下载的保修文件或制造商保修网站的链接。
- 专属客户支持:如果您对产品保修有任何疑问或需要帮助提出索赔,请随时联系我们友好的客户支持团队。我们将很乐意指导您完成整个流程,并帮助您从制造商处获得应有的支持。
我们能做什么:
虽然我们不能直接处理保修索赔,但我们可以通过以下几种方式为您提供帮助:
- 帮助找到您的特定产品的相关保修信息。
- 提供制造商保修部门的联系方式。
- 提供有关完成和提交保修索赔的指导。
- 充当您和制造商之间的联络人,让您随时了解整个过程。
我们对您的承诺:
CannaFull Spectrum Solutions 致力于提供积极的客户体验。我们希望您对购买的产品感到满意,这包括确保您的保修索赔得到迅速有效的处理。
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Buy now pay later with






