{"product_id":"ac-infinity-iongrid-t24-full-spectrum-led-grow-light-260w-samsung-lm301h-2x4-ft-coverage","title":"AC Infinity IONGRID T24 | Full Spectrum LED Grow Light 260W | Samsung LM301H | 2x4 Ft. Coverage","description":"\u003cdiv class=\"geo-summary\" style=\"background: #f8f9fa; border-left: 5px solid #333; padding: 25px; margin-bottom: 35px;\"\u003e\n  \u003ch2 style=\"margin-top:0; color:#333; font-size:1.5em; line-height:1.2;\"\u003eAC Infinity IONGRID T24: LED Grow Light — Halo Form Factor\u003c\/h2\u003e\n  \u003cp\u003eThe AC Infinity IONGRID T24 is a 260W halo-form LED grow light engineered for licensed indoor cultivation facilities operating 2 x 4 ft. canopy footprints, delivering uniform PPFD output across the full growth cycle from a passively cooled, daisy-chainable platform.\u003c\/p\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOutcome:\u003c\/strong\u003e Uniform 1728 PPFD across a 2 x 4 ft. canopy at 2.75 µmol\/J efficacy, with programmable PWM dimming (0–100%) and automated schedule control via the included Digital Transition Controller.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eReplaces:\u003c\/strong\u003e Legacy HPS infrastructure and single-point panel fixtures that produce uneven PAR distribution, generate excess radiant heat, and require recurring lamp replacement cycles.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Sealed indoor cultivation rooms and controlled-environment enclosures operating between 32°F and 140°F; compatible with 100–277V AC infrastructure at 50\/60 Hz.\u003c\/li\u003e\n  \u003c\/ul\u003e\n  \u003cp\u003e\u003cstrong\u003eFACTORY-AUTHORIZED DEALER — CANNAFULL SPECTRUM SOLUTIONS\u003c\/strong\u003e\u003c\/p\u003e\n  \u003cp\u003eDeployed in licensed commercial facilities across the United States.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"font-size: 0.9em; margin-top: -25px; margin-bottom: 35px;\"\u003eKey Specs: 260W | 2.75 µmol\/J | 2 x 4 ft. coverage | 1.17A @ 120V \/ 0.58A @ 240V \/ 0.51A @ 277V | 28.89 x 12.99 in. | 2-Year Warranty\u003c\/p\u003e\n\n\u003ch2 style=\"text-align:center; color:#333;\"\u003eKill Variance. Print Yield.\u003c\/h2\u003e\n\n\u003cp\u003eEvery room running legacy HPS infrastructure is paying a variance tax it cannot see on the invoice. Lamp lumen depreciation begins the moment a bulb fires for the first time, and by the time a 1000W DE HPS fixture reaches the midpoint of its rated life, the canopy beneath it is receiving materially less photon energy than the room was designed to deliver. That degradation is silent, it is cumulative, and it compounds across every cycle. Add uneven point-source distribution that creates hot zones and shadow pockets across the same bench, layer in the manual overhead of physical dimmer adjustments and lamp swap scheduling, and the operational picture becomes clear: the facility is not running at the yield model it was built to hit. The enemy is not any single component failure — it is the aggregate drift that legacy infrastructure normalizes over time.\u003c\/p\u003e\n\n\u003cp\u003eAfter deployment of the IONGRID T24, the operational picture changes at the infrastructure level. Canopy uniformity is no longer a function of lamp age or technician attention — it is a function of fixture geometry and programmed output. Scheduled photoperiods execute automatically, sunrise and sunset transitions run on defined curves, and backup memory holds the program through any power interruption. Lamp replacement cycles are removed from the maintenance calendar entirely. The facility runs the same photon delivery on day one of a cycle as it does on day sixty, and the control architecture that governs that output requires no manual intervention between scheduled audits.\u003c\/p\u003e\n\n\u003cp\u003eThe mechanism behind that operational stability is the IONGRID T24's four-sided halo form factor — a linear bar light architecture bent into a closed perimeter that distributes photon output from four angles simultaneously rather than from a single central point. The 560 Samsung LM301H diodes are arrayed across that perimeter and driven at 260W to produce 1728 PPFD across the 2 x 4 ft. target footprint at 2.75 µmol\/J system efficacy. The spectral platform combines 660nm deep red, 730nm far-red, 3000K warm white, and 5000K cool white channels to support the full growth cycle from vegetative establishment through reproductive development. The raised LED driver sits on an aluminum heatsink with thermal compound interface, passively dissipating heat without fans or moving parts, eliminating both acoustic output and mechanical failure points in the thermal management system. The Digital Transition Controller ships with the fixture and provides 0–100% PWM dimming, programmable timers, cycle scheduling, and daisy-chain ports for multi-fixture coordination across a room. In practical terms, the IONGRID T24 delivers 1728 PPFD across a 2 x 4 ft. canopy at 260W draw, operating at 1.17A on 120V or 0.51A on 277V infrastructure.\u003c\/p\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0587\/4450\/4455\/files\/IONBOARDlandingA2_046dd894-2766-4410-9ef3-cb1d632a12b8.jpg?v=1746684385\" alt=\"AC Infinity IONBOARD S22 full board view, product identity shot — hero image for IONGRID T24 hook section\" style=\"width:100%; height:auto; margin:25px 0; border-radius:4px;\"\u003e\n\n\u003ch3 style=\"color:#333;\"\u003eWhere This Belongs (and Doesn't)\u003c\/h3\u003e\n\u003cp style=\"margin:8px 0;\"\u003e\u003cem\u003eNot recommended for circuits under ~2.17A @120V or ~1.08A @240V per fixture, or unsealed rooms lacking HVAC capacity for expected thermal load.\u003c\/em\u003e\u003c\/p\u003e\n\n\n\u003cp\u003e\u003cem\u003eMinimum electrical requirement: a dedicated 15A circuit at 120V or equivalent at 240V\/277V. HVAC load planning must account for the fixture's thermal output; consult your mechanical engineer before finalizing room layout.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003cdiv style=\"display:flex; gap:20px; margin:20px 0; flex-wrap:wrap;\"\u003e\n  \u003cdiv style=\"flex:1; min-width:240px; background:#f0f7ff; border-left:4px solid #007bff; padding:16px;\"\u003e\n    \u003ch4 style=\"margin-top:0; color:#333;\"\u003eEngineered For\u003c\/h4\u003e\n    \u003cul\u003e\n      \u003cli\u003eLicensed indoor cultivation facilities operating 2 x 4 ft. canopy footprints (veg and flower coverage: 2 x 4 ft.)\u003c\/li\u003e\n      \u003cli\u003eControlled-environment enclosures requiring uniform PPFD distribution without point-source hot zones\u003c\/li\u003e\n      \u003cli\u003eFacilities transitioning away from HPS infrastructure seeking zero lamp-replacement maintenance cycles\u003c\/li\u003e\n      \u003cli\u003eMulti-fixture rooms requiring coordinated dimming and schedule control via daisy-chained Digital Transition Controllers\u003c\/li\u003e\n      \u003cli\u003eOperations running 100–277V AC infrastructure at 50\/60 Hz\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"flex:1; min-width:240px; background:#fff8f8; border-left:4px solid #cc0000; padding:16px;\"\u003e\n    \u003ch4 style=\"margin-top:0; color:#333;\"\u003eNot Recommended For\u003c\/h4\u003e\n    \u003cul\u003e\n      \u003cli\u003eCanopy footprints larger than 2 x 4 ft. without supplemental fixture coverage\u003c\/li\u003e\n      \u003cli\u003eOutdoor or semi-outdoor installations where IP rating has not been independently verified for the deployment environment\u003c\/li\u003e\n      \u003cli\u003eFacilities without stable 100–277V AC power infrastructure\u003c\/li\u003e\n      \u003cli\u003eOperations requiring UV supplementation — the IONGRID T24 does not include a UV spectral channel; pair with IONBEAM U2 or U4 for targeted UV delivery\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cp\u003e\u003cstrong\u003eInfrastructure Note:\u003c\/strong\u003e The IONGRID T24 draws 1.17A at 120V, 0.58A at 240V, and 0.51A at 277V. Multi-fixture deployments must be load-calculated per circuit before installation. The Digital Transition Controller supports daisy-chaining; verify controller port capacity against total fixture count before commissioning.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#333;\"\u003eHow It Works\u003c\/h3\u003e\n\n\u003cp\u003eThe IONGRID T24 begins with a form factor decision that separates it from conventional panel and bar configurations: the linear bar light architecture is bent into a four-sided closed perimeter — the halo — so that photon output originates from all four sides of the canopy boundary simultaneously. This geometry eliminates the center-heavy PPFD distribution that single-point and flat-panel fixtures produce, delivering a more uniform photon density map across the 2 x 4 ft. target footprint without requiring the operator to fine-tune mounting height to compensate for edge falloff.\u003c\/p\u003e\n\n\u003cp\u003eThe 560 Samsung LM301H diodes populating that perimeter are driven at 260W across four spectral channels: 660nm deep red for photosynthetic peak absorption, 730nm far-red for photoperiod signaling and canopy penetration, 3000K warm white for broad-spectrum vegetative support, and 5000K cool white for blue-range developmental stimulus. This four-channel architecture supports the full growth cycle — germination, vegetative establishment, and reproductive development — without requiring fixture swaps or supplemental bar additions for standard production runs. System efficacy is rated at 2.75 µmol\/J, producing 1728 PPFD at the canopy surface across the rated footprint.\u003c\/p\u003e\n\n\u003cp\u003eThermal management is handled passively. The LED driver is raised above the aluminum heatsink frame on a thermal compound interface, allowing heat to conduct away from the diode array and dissipate through the heatsink without fans or active cooling components. This architecture eliminates acoustic output entirely and removes the mechanical failure mode that fan-cooled fixtures introduce over a 50,000-hour rated service life. The Digital Transition Controller — included with the fixture — governs output through 0–100% PWM dimming, programmable timer and cycle scheduling, sunrise\/sunset transition curves, and backup memory that retains program state through power interruptions. Daisy-chain ports on the controller allow multi-fixture coordination from a single control point, reducing the per-fixture management overhead in multi-light rooms. In practical terms, the IONGRID T24 delivers 1728 PPFD across a 2 x 4 ft. canopy at 260W draw, operating across 100–277V AC at 50\/60 Hz with a 50,000-hour rated LED lifespan.\u003c\/p\u003e\n\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0587\/4450\/4455\/files\/IONBOARDlandingD2.jpg?v=1746684461\" alt=\"AC Infinity IONBOARD S22 spectrum distribution showing Samsung LM301H full-spectrum channel layout — technical diagram for IONGRID T24 core mechanism section\" style=\"width:100%; height:auto; margin:25px 0; border-radius:4px;\"\u003e\n\n\u003cdiv style=\"background:#f0f7ff; border-left:5px solid #007bff; padding:16px; margin:25px 0;\"\u003e\n  \u003ch4 style=\"margin:0 0 8px; font-family:Arial,sans-serif; color:#111; font-size:1.1em;\"\u003eCommercial Assurance\u003c\/h4\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 2-Year Product Warranty from AC Infinity. Claims processed through Cannafull Spectrum Solutions — contact (888) 378-0017 or sales@cannafullspec.com to initiate. Return Authorization (RA) required before any unit is returned.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003e30-Day Return:\u003c\/strong\u003e Free and easy returns within 30 days of delivery. RA number required. Item must be in original condition. See full terms at cannafullspec.com\/pages\/return-policy.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eLED Lifespan:\u003c\/strong\u003e 50,000 hours rated service life per AC Infinity source data for the IONGRID T24.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFactory-Authorized Dealer:\u003c\/strong\u003e Cannafull Spectrum Solutions is a factory-authorized AC Infinity dealer. All units ship new, factory-sealed, with full manufacturer warranty intact.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color:#333;\"\u003eSystem Integration\u003c\/h3\u003e\n\n\u003cp\u003eTo operate this platform at peak efficiency, verify your ecosystem matches these requirements:\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eController:\u003c\/strong\u003e Digital Transition Controller included. For multi-room or app-based control, verify compatibility with AC Infinity UIS ecosystem controllers. Expansion dongles for additional fixture integration are sold separately.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Rope hanging hardware included. Verify structural load capacity of mounting points before installation. Fixture dimensions are 28.89 x 12.99 in. (73.4 x 33.0 cm); confirm clearance within the enclosure before ordering.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e NEMA 1-15 Type-A US plug with 12 ft. power cord. Input voltage range 100–277V AC at 50\/60 Hz. Draw is 1.17A at 120V, 0.58A at 240V, 0.51A at 277V. Size circuits accordingly for multi-fixture deployments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHVAC:\u003c\/strong\u003e Passive thermal management eliminates fan heat contribution, but the fixture's 260W electrical load still converts to thermal output that must be accounted for in room HVAC sizing. Consult your mechanical engineer for load calculations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSpectral Supplementation:\u003c\/strong\u003e The IONGRID T24 does not include a UV channel. Facilities requiring UV delivery for secondary metabolite expression should integrate IONBEAM U2 or U4 bars as supplemental fixtures within the UIS ecosystem.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv class=\"roi-mini\" style=\"background:#f0f7ff; border-left:5px solid #007bff; padding:16px; margin:25px 0;\"\u003e  \u003ch3 style=\"margin-top:0;font-family: Arial, sans-serif; color:#111; font-size:1.1em;\"\u003eCAPEX ROI Mini‑Calculator (Energy Only)\u003c\/h3\u003e  \u003cul style=\"margin:0 0 10px 18px;\"\u003e    \u003cli\u003e\n\u003cstrong\u003eFixture Wattage:\u003c\/strong\u003e 260 W\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eEnergy Cost:\u003c\/strong\u003e $0.12\/kWh\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003ePhotoperiod:\u003c\/strong\u003e 12 h\/day × 365 days\/yr\u003c\/li\u003e  \u003c\/ul\u003e  \u003cul style=\"margin:6px 0 10px 18px;\"\u003e    \u003cli\u003e\n\u003cstrong\u003ePer Fixture \/ Year:\u003c\/strong\u003e $136.66\u003c\/li\u003e    \u003cli style=\"color:#0056b3;\"\u003e\n\u003cstrong\u003e10-Unit Room \/ Year:\u003c\/strong\u003e $1366.56\u003c\/li\u003e    \u003cli style=\"color:#0056b3;\"\u003e\n\u003cstrong\u003e20-Unit Room \/ Year:\u003c\/strong\u003e $2733.12\u003c\/li\u003e    \u003cli style=\"color:#0056b3;\"\u003e\n\u003cstrong\u003e50-Unit Room \/ Year:\u003c\/strong\u003e $6832.80\u003c\/li\u003e  \u003c\/ul\u003e  \u003cp style=\"font-size:0.85em;color:#666;margin:0;\"\u003e\u003cem\u003eEstimate is energy-only. Adjust assumptions for your facility; excludes HVAC interactions, rebates, and demand charges.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv class=\"comparison-block\" style=\"margin:24px 0; padding:16px; border:1px solid #e6e6e6; background:#fafafa;\" role=\"region\" aria-label=\"Product Comparison Table\"\u003e\n\u003ch2 style=\"margin:0 0 10px; font-family:Arial,sans-serif; color:#111;\"\u003eComparison: AC Infinity IONGRID T24 260W Professional Cultivation vs. Legacy 1000W DE HPS\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 12px; color:#333; font-size:0.95em;\"\u003eSanity-check your infrastructure planning against legacy alternatives.\u003c\/p\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; font-size:0.95em; border:1px solid #eee;\" role=\"grid\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#f6f6f6;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003ePlanning Factor\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eAC Infinity IONGRID T24 260W Professional Cultivation (260W)\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eLegacy 1000W DE HPS\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eOperational Impact\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e\u003cstrong\u003eWattage Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e260 W\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e1000 W\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eWattage drives electrical planning. Verify nameplate ratings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e\u003cstrong\u003eHeat Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e~887 BTU\/hr\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e3,412 BTU\/hr\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eHVAC sizing must account for total heat rejection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e\u003cstrong\u003eSpectrum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e660nm, 730nm, 3000K, 5000K\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eYellow\/Orange (HPS)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eBroadband spectrum supports secondary metabolite production.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e\u003cstrong\u003eDimming\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e0-100% PWM\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eLimited \/ None\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003ePrecision DLI ramping allows for energy savings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e\u003cstrong\u003eBulb Replacement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e$0 (No maintenance)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e~$600+ (5-Year TCO)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eEliminates maintenance labor and consumable costs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e2-Year Product Warranty\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eVaries (1-3 Years)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eFunctions as operational security for your facility.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\u003ch3 style=\"color:#333;\"\u003eFacility Integration Data\u003c\/h3\u003e\n\n\u003cp\u003eUse the data below to model fleet-level electrical cost savings and evaluate the IONGRID T24 against legacy 1000W DE HPS infrastructure on key operational metrics.\u003c\/p\u003e\n\n\u003cdiv style=\"background:#f0f7ff; border-left:5px solid #007bff; padding:16px; margin:25px 0;\"\u003e\n  \u003ch4 style=\"margin:0 0 8px; font-family:Arial,sans-serif; color:#111; font-size:1.1em;\"\u003eROI Mini-Calculator — Annual Energy Cost Comparison\u003c\/h4\u003e\n  \u003cp style=\"font-size:0.85em; color:#555; margin-bottom:12px;\"\u003eAssumes 18\/6 photoperiod (6,570 hours\/year), $0.12\/kWh blended rate. HPS baseline: 1,150W per fixture (lamp + ballast). IONGRID T24: 260W per fixture. Figures are estimates for planning purposes only.\u003c\/p\u003e\n  \u003cdiv class=\"facility-data electrical\" style=\"margin:24px 0;\"\u003e\n\u003ch3 style=\"margin:0 0 10px; font-size:1.05em;\"\u003eElectrical \/ Thermal\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; font-size:0.95em; border:1px solid #eee;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"background:#f6f6f6; border:1px solid #ddd; text-align:left; padding:8px;\"\u003eSKU\u003c\/th\u003e\n\u003cth style=\"background:#f6f6f6; border:1px solid #ddd; text-align:left; padding:8px;\"\u003eW (W)\u003c\/th\u003e\n\u003cth style=\"background:#f6f6f6; border:1px solid #ddd; text-align:left; padding:8px;\"\u003eBTU\/hr\u003c\/th\u003e\n\u003cth style=\"background:#f6f6f6; border:1px solid #ddd; text-align:left; padding:8px;\"\u003eInput V\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eAC-IGT24\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e260\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e887\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e100-277V AC\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"font-size:0.85em; color:#666; margin:8px 0 0;\"\u003e\u003cem\u003eBTU\/hr shown is an engineering estimate computed from wattage using 3.412 BTU\/hr per watt. Verify HVAC loads against manufacturer specifications and local code.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"facility-data physical\" style=\"margin:24px 0;\"\u003e\n\u003ch3 style=\"margin:0 0 10px; font-size:1.05em;\"\u003ePhysical\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; font-size:0.95em; border:1px solid #eee;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"background:#f6f6f6; border:1px solid #ddd; text-align:left; padding:8px;\"\u003eSKU\u003c\/th\u003e\n\u003cth style=\"background:#f6f6f6; border:1px solid #ddd; text-align:left; padding:8px;\"\u003eDimensions\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eAC-IGT24\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e28.89 x 12.99 in. (73.4 x 33.0 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"facility-data light-engine\" style=\"margin:24px 0;\"\u003e\n\u003ch3 style=\"margin:0 0 10px; font-size:1.05em;\"\u003eLight Engine\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; font-size:0.95em; border:1px solid #eee;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"background:#f6f6f6; border:1px solid #ddd; text-align:left; padding:8px;\"\u003eSKU\u003c\/th\u003e\n\u003cth style=\"background:#f6f6f6; border:1px solid #ddd; text-align:left; padding:8px;\"\u003eSpectrum\u003c\/th\u003e\n\u003cth style=\"background:#f6f6f6; border:1px solid #ddd; text-align:left; padding:8px;\"\u003eDimming\u003c\/th\u003e\n\u003cth style=\"background:#f6f6f6; border:1px solid #ddd; text-align:left; padding:8px;\"\u003ePPF (µmol\/s)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eAC-IGT24\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e660nm, 730nm, 3000K, 5000K\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e0-100% PWM\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e1728 PPFD\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; font-size:0.9em; margin-top:20px;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background:#333; color:#fff;\"\u003e\n      \u003cth style=\"padding:10px; text-align:left;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:10px; text-align:center;\"\u003eIONGRID T24\u003c\/th\u003e\n      \u003cth style=\"padding:10px; text-align:center;\"\u003eLegacy 1000W DE HPS\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"background:#fff;\"\u003e\n      \u003ctd style=\"padding:8px; border-bottom:1px solid #eee;\"\u003eSystem Wattage\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; text-align:center; border-bottom:1px solid #eee;\"\u003e260W\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; text-align:center; border-bottom:1px solid #eee;\"\u003e~1,150W (lamp + ballast)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f8f9fa;\"\u003e\n      \u003ctd style=\"padding:8px; border-bottom:1px solid #eee;\"\u003eEfficacy\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; text-align:center; border-bottom:1px solid #eee;\"\u003e2.75 µmol\/J\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; text-align:center; border-bottom:1px solid #eee;\"\u003e~1.7 µmol\/J\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#fff;\"\u003e\n      \u003ctd style=\"padding:8px; border-bottom:1px solid #eee;\"\u003ePPFD (µmol\/m²\/s)\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; text-align:center; border-bottom:1px solid #eee;\"\u003e1728 @ 2 x 4 ft.\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; text-align:center; border-bottom:1px solid #eee;\"\u003eVariable \/ degrades with lamp age\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f8f9fa;\"\u003e\n      \u003ctd style=\"padding:8px; border-bottom:1px solid #eee;\"\u003eSpectrum\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; text-align:center; border-bottom:1px solid #eee;\"\u003e660nm, 730nm, 3000K, 5000K\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; text-align:center; border-bottom:1px solid #eee;\"\u003eBroadband \/ fixed, no IR channel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#fff;\"\u003e\n      \u003ctd style=\"padding:8px; border-bottom:1px solid #eee;\"\u003eDimming\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; text-align:center; border-bottom:1px solid #eee;\"\u003e0–100% PWM\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; text-align:center; border-bottom:1px solid #eee;\"\u003eNot available (fixed output)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f8f9fa;\"\u003e\n      \u003ctd style=\"padding:8px; border-bottom:1px solid #eee;\"\u003eLamp Replacement\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; text-align:center; border-bottom:1px solid #eee;\"\u003eNone — 50,000-hr LED lifespan\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; text-align:center; border-bottom:1px solid #eee;\"\u003eEvery 10,000–12,000 hrs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#fff;\"\u003e\n      \u003ctd style=\"padding:8px; border-bottom:1px solid #eee;\"\u003eThermal Output\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; text-align:center; border-bottom:1px solid #eee;\"\u003ePassive \/ no fan noise\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; text-align:center; border-bottom:1px solid #eee;\"\u003eHigh radiant heat \/ active cooling required\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f8f9fa;\"\u003e\n      \u003ctd style=\"padding:8px; border-bottom:1px solid #eee;\"\u003eAutomated Scheduling\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; text-align:center; border-bottom:1px solid #eee;\"\u003eTimers, cycles, sunrise\/sunset, backup memory\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; text-align:center; border-bottom:1px solid #eee;\"\u003eExternal timer required \/ no transition curves\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#fff;\"\u003e\n      \u003ctd style=\"padding:8px;\"\u003eWarranty\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; text-align:center;\"\u003e2 Years\u003c\/td\u003e\n      \u003ctd style=\"padding:8px; text-align:center;\"\u003eTypically 1 Year (ballast only)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#333;\"\u003eOperator Field Note\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrical Draw:\u003c\/strong\u003e The IONGRID T24 draws 1.17A at 120V, 0.58A at 240V, and 0.51A at 277V. In multi-fixture deployments, calculate total amperage per circuit before energizing. Do not share circuits with high-draw HVAC or dehumidification equipment without verified load calculations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Load:\u003c\/strong\u003e Rope hanging hardware is included. Verify that the mounting structure — tent frame, overhead rail, or ceiling anchor — is rated for the fixture weight before installation. Confirm clearance dimensions against the 28.89 x 12.99 in. (73.4 x 33.0 cm) fixture footprint.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eController Placement:\u003c\/strong\u003e The Digital Transition Controller can be detached from the fixture and mounted remotely. Controller dimensions are 3.30 x 1.18 x 0.70 in. (8.4 x 3.0 x 1.8 cm). Daisy-chain port capacity should be verified against total fixture count before commissioning a multi-light array.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Temperature Range:\u003c\/strong\u003e Rated for 32°F to 140°F ambient. Facilities operating at temperature extremes within this range should monitor heatsink surface temperature during initial commissioning to confirm passive cooling is performing within spec.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Cord Length:\u003c\/strong\u003e The included power cord is 12 ft. Plan outlet placement and cord routing before finalizing fixture position. Extension cords are not recommended for permanent installation; consult a licensed electrician for hardwired drop configurations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNo UV Channel:\u003c\/strong\u003e The IONGRID T24 spectral platform (660nm, 730nm, 3000K, 5000K) does not include a UV output channel. Facilities requiring UV delivery for secondary metabolite expression must integrate supplemental UV fixtures separately.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv class=\"faq-section\" itemscope itemtype=\"https:\/\/schema.org\/FAQPage\"\u003e\n  \u003ch3 style=\"color:#333;\"\u003eOperator FAQ\u003c\/h3\u003e\n\n  \u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n    \u003csummary itemprop=\"name\"\u003eQ: What amperage and circuit configuration does the IONGRID T24 require?\u003c\/summary\u003e\n    \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n      \u003cp itemprop=\"text\"\u003eA: The IONGRID T24 draws 1.17A at 120V, 0.58A at 240V, and 0.51A at 277V. For single-fixture installations on 120V, a standard 15A dedicated circuit is sufficient. For multi-fixture deployments, calculate total amperage per circuit at your operating voltage and apply the 80% continuous load rule (NEC 210.19) before finalizing circuit sizing. Do not share circuits with high-draw equipment without verified load calculations from a licensed electrician.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n    \u003csummary itemprop=\"name\"\u003eQ: What controller is included, and what modes does it support?\u003c\/summary\u003e\n    \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n      \u003cp itemprop=\"text\"\u003eA: The IONGRID T24 ships with AC Infinity's Digital Transition Controller. It supports 0–100% PWM dimming, programmable timer and cycle scheduling, sunrise\/sunset transition curves, and backup memory that retains program state through power interruptions. The controller includes daisy-chain ports for coordinating multiple fixtures from a single control point. For app-based or multi-zone control, verify compatibility with AC Infinity UIS ecosystem controllers; expansion dongles for additional fixture integration are sold separately.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n    \u003csummary itemprop=\"name\"\u003eQ: What is the recommended mounting height for the IONGRID T24?\u003c\/summary\u003e\n    \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n      \u003cp itemprop=\"text\"\u003eA: AC Infinity source data does not specify a single recommended mounting height for the IONGRID T24. The rated PPFD of 1728 µmol\/m²\/s is measured at the canopy surface across the 2 x 4 ft. footprint. Mounting height will affect PPFD delivery at the canopy; operators should use a calibrated PAR meter to verify canopy-level readings at their specific mounting height during initial commissioning. Rope hanging hardware is included to allow height adjustment. Contact Cannafull Spectrum Solutions at (888) 378-0017 or sales@cannafullspec.com for application-specific guidance.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n    \u003csummary itemprop=\"name\"\u003eQ: What are the vegetative and flowering coverage dimensions?\u003c\/summary\u003e\n    \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n      \u003cp itemprop=\"text\"\u003eA: Per AC Infinity source data, the IONGRID T24 is rated for a 2 x 4 ft. coverage area for both vegetative and flowering stages. This coverage rating applies to the fixture operating at full output. Operators running reduced dimming levels should verify canopy PPFD with a PAR meter to confirm target DLI is being met at the reduced output setting.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n    \u003csummary itemprop=\"name\"\u003eQ: What is the rated lifespan, and what maintenance does the fixture require over that period?\u003c\/summary\u003e\n    \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n      \u003cp itemprop=\"text\"\u003eA: The IONGRID T24 is rated for 50,000 hours of LED service life per AC Infinity source data. The passive thermal management system — raised driver over aluminum heatsink with thermal compound interface — contains no fans or moving parts, eliminating the primary mechanical failure mode in the thermal subsystem. Routine maintenance is limited to periodic cleaning of the heatsink surface to prevent dust accumulation that could impede passive heat dissipation. No lamp replacement cycles are required over the rated service life.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n    \u003csummary itemprop=\"name\"\u003eQ: How do I initiate a warranty claim through Cannafull Spectrum Solutions?\u003c\/summary\u003e\n    \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n      \u003cp itemprop=\"text\"\u003eA: The IONGRID T24 carries a 2-Year Product Warranty from AC Infinity. To initiate a claim, contact Cannafull Spectrum Solutions directly at (888) 378-0017 or sales@cannafullspec.com. A Return Authorization (RA) number is required before any unit can be returned for warranty service. Do not ship units without an RA number — unauthorized returns cannot be processed. Have your order number, purchase date, and a description of the defect ready when you contact our team. Cannafull Spectrum Solutions is a factory-authorized AC Infinity dealer; all warranty claims are processed with full manufacturer support.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/details\u003e\n\u003c\/div\u003e\n\n\u003ch3 style=\"color:#333;\"\u003eShipping \u0026amp; Logistics\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e Ships from Cannafull Spectrum Solutions' authorized fulfillment network within the contiguous 48 United States.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProcessing:\u003c\/strong\u003e Orders are processed within 1–2 business days of payment confirmation. Tracking information is provided upon shipment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDamage:\u003c\/strong\u003e Inspect all shipments within 48 hours of delivery. Document any damage with photographs and contact Cannafull Spectrum Solutions immediately at (888) 378-0017 or sales@cannafullspec.com. Claims submitted after 48 hours may not be eligible for carrier damage resolution.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReturns:\u003c\/strong\u003e Free and easy returns accepted within 30 days of delivery. A Return Authorization (RA) number is required before returning any item. Items must be in original condition and packaging. Contact our team to initiate the RA process.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRestocking Fee:\u003c\/strong\u003e Returns of non-defective items are subject to a restocking fee of up to 25% per our Return Policy. Review full terms at cannafullspec.com\/pages\/return-policy before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eQuestions? (888) 378-0017 or sales@cannafullspec.com\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ch3 style=\"color:#333;\"\u003eWhat's in the Box\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eAC Infinity IONGRID T24 LED Grow Light (AC-IGT24)\u003c\/li\u003e\n  \u003cli\u003eDigital Transition Controller\u003c\/li\u003e\n  \u003cli\u003eRope hanging hardware\u003c\/li\u003e\n  \u003cli\u003ePower cord (12 ft., NEMA 1-15 Type-A US plug)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp style=\"font-size:0.85em; color:#666;\"\u003e\u003cem\u003eNote: Box contents are based on available manufacturer data. Verify complete contents upon receipt. Contact Cannafull Spectrum Solutions at (888) 378-0017 if any components are missing or damaged.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch3 style=\"color:#333;\"\u003eRegional Compliance \u0026amp; Deployment Notes\u003c\/h3\u003e\n\n\u003cdiv style=\"background:#f4f4f4; padding:15px; border-radius:5px; margin-top:20px;\"\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAll U.S. States:\u003c\/strong\u003e Available for commercial deployment across all 50 U.S. states. Verify local electrical code compliance — including circuit sizing, grounding requirements, and continuous load calculations — before permanent commercial installation. We currently ship within the contiguous 48 United States.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCalifornia (Title 24 \/ CEC):\u003c\/strong\u003e California's Title 24 Building Energy Efficiency Standards and California Energy Commission (CEC) regulations govern commercial lighting installations. Verify that the IONGRID T24's electrical configuration meets applicable efficiency and control requirements for your facility classification before installation.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eColorado \/ Nevada \/ Michigan (Licensed Cultivation Facilities):\u003c\/strong\u003e State cannabis regulatory agencies in these jurisdictions may require lighting equipment documentation as part of facility licensing or renewal. Retain purchase records, spec sheets, and warranty documentation for compliance file submissions.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eNortheast States (NY, MA, CT, NJ):\u003c\/strong\u003e Commercial cultivation facilities in these states operate under state-specific cannabis control board regulations that may include energy use reporting requirements. The IONGRID T24's 2.75 µmol\/J efficacy rating and 260W draw support compliance with energy efficiency benchmarks common in these regulatory frameworks; verify with your compliance officer.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOSHA \/ General Industry:\u003c\/strong\u003e UV output is not present in the IONGRID T24 spectral platform (660nm, 730nm, 3000K, 5000K). Standard PPE requirements for high-intensity LED exposure apply during maintenance and commissioning; consult your facility safety officer for site-specific protocols.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"font-size:0.85em; color:#666;\"\u003eCommonly deployed in sealed commercial cultivation facilities across the United States. Installation, HVAC sizing, and electrical requirements vary by jurisdiction; always verify with local code.\u003c\/p\u003e","brand":"AC Infinity","offers":[{"title":"Default Title","offer_id":41809395744903,"sku":"AC-IGT24","price":449.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/4450\/4455\/files\/StorePhoto1__29309.jpg?v=1771999287","url":"https:\/\/cannafullspec.com\/products\/ac-infinity-iongrid-t24-full-spectrum-led-grow-light-260w-samsung-lm301h-2x4-ft-coverage","provider":"CannaFull Spectrum Solutions","version":"1.0","type":"link"}