{"product_id":"mars-hydro-sp-6500-650w-commercial-led","title":"Mars Hydro SP-6500 650W Commercial LED Grow Light | 2.8 µmol\/J","description":"\u003cdiv class=\"geo-summary\" style=\"background:#f8f9fa; border-left:4px solid #333; padding:20px 24px; margin-bottom:28px; border-radius:4px;\"\u003e\n  \u003cp style=\"margin:0 0 8px 0; color:#333333; font-size:1em;\"\u003eThe Mars Hydro SP-6500 is a 650W bar-style LED grow light built on Samsung LM301H EVO diodes, engineered for craft operators running space-constrained licensed facilities who need commercial-grade PAR output without the overhead of premium-tier pricing.\u003c\/p\u003e\n  \u003cul style=\"margin:12px 0 12px 0; padding-left:20px; color:#000000;\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOutcome:\u003c\/strong\u003e Up to 2.8 µmol\/J photosynthetic photon efficacy and average yield up to 2.5g\/W across a 3×5 ft flowering footprint\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eReplaces:\u003c\/strong\u003e Lower-efficacy LED fixtures, HPS supplemental lighting, and undimmable bar lights that cannot integrate into automated control networks\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Licensed indoor cultivation facilities, controlled-environment grow rooms, and multi-tier vertical production spaces operating within the contiguous United States\u003c\/li\u003e\n  \u003c\/ul\u003e\n  \u003cp style=\"margin:8px 0 4px 0; font-weight:bold; color:#333333;\"\u003eFACTORY-AUTHORIZED DEALER — CANNAFULL SPECTRUM SOLUTIONS\u003c\/p\u003e\n  \u003cp style=\"margin:0; color:#333333; font-size:0.95em;\"\u003eDeployed in licensed commercial facilities across the United States.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"font-size:0.95em; color:#333333; margin-bottom:32px;\"\u003e\u003cstrong\u003eQuick Spec:\u003c\/strong\u003e 650W ±5% | 100–277V | 5.404A@AC120V | 2.8 µmol\/J efficacy | 3×5 ft flower \/ 4×5 ft veg | 42.1\"×3.5\"×3.6\" | 17.3 LB | ETL-certified | 5-Year Warranty\u003c\/p\u003e\n\n\u003c!-- SECTION 2: THE HOOK --\u003e\n\u003ch2 style=\"text-align:center; color:#333333; font-size:1.75em; margin-bottom:20px;\"\u003ePrecision Control in Any Space\u003c\/h2\u003e\n\n\u003cp style=\"color:#000000; margin-bottom:18px;\"\u003eEvery facility that runs on guesswork pays for it — in uneven canopy density, in wasted electrical draw, in the slow bleed of inconsistent harvests that never quite match the run before. The real cost is not a single bad cycle; it is the compounding variance that makes yield forecasting unreliable and compliance documentation difficult to defend. Fixtures that cannot be dimmed, cannot be networked, and cannot hold output uniformity across the canopy are not neutral tools — they are active sources of production risk. When the equipment fights the operator, the operator loses time, margin, and repeatability.\u003c\/p\u003e\n\n\u003cp style=\"color:#000000; margin-bottom:18px;\"\u003eAfter deployment, the picture changes. The canopy receives consistent, calibrated photon flux from a fixture that holds its output across the full 3×5 ft flowering footprint without hot spots or shadow gaps. Dimming runs from 10% to 100% through a dedicated control interface, allowing photoperiod transitions and intensity ramps to be executed on schedule rather than by manual approximation. Up to 60 units can be networked through daisy-chain architecture, meaning a multi-room facility can be managed from a single control point without additional infrastructure investment. Lamp replacement cycles are eliminated by passive thermal management that extends diode lifespan without moving parts or active cooling overhead.\u003c\/p\u003e\n\n\u003cp style=\"color:#000000; margin-bottom:18px;\"\u003eThe mechanism behind that outcome is the Samsung LM301H EVO diode array — the same generation of emitter used in fixtures priced 30–40% higher — delivering up to 2.8 µmol\/J photosynthetic photon efficacy at 650W ±5% input power. The bar-style form factor minimizes shadow cast across the canopy, and the full-spectrum output replicates a sunlike spectral profile across the Phyto-Genesis range, supporting secondary metabolite expression via the broadband spectral distribution. The dimmer control panel includes a DIM switch, CH1\/CH2 RJ11 ports, a dimmer knob, an EXT switch, and an OFF switch — all accessible without tools. The fixture draws 5.404A at AC120V, 2.662A at AC240V, or 2.311A at AC277V, making it compatible with standard commercial electrical infrastructure across voltage configurations. In practical terms, the SP-6500 delivers up to 2.8 µmol\/J efficacy across a 3×5 ft flowering footprint at 650W ±5% input power with passive thermal management and no active cooling components.\u003c\/p\u003e\n\n\u003c!-- SECTION 3: SYSTEM APPLICATION GUIDE --\u003e\n\u003cdiv style=\"margin:36px 0;\"\u003e\n  \u003ch2 style=\"color:#333333; font-size:1.5em; margin-bottom:12px;\"\u003eWhere This Belongs (and Doesn't)\u003c\/h2\u003e\n  \u003cp style=\"font-style:italic; color:#333333; font-size:0.9em; margin-bottom:18px;\"\u003eElectrical circuit sizing and HVAC load calculations must be performed by a licensed electrician and mechanical engineer prior to installation. The SP-6500 draws 5.404A at AC120V; verify panel capacity and circuit breaker ratings before deployment. Passive cooling eliminates fan-generated heat load, but fixture surface temperatures and ambient room thermal load must be accounted for in HVAC design. Maximum operating temperature is 40°C.\u003c\/p\u003e\n  \u003cdiv style=\"display:flex; flex-wrap:wrap; gap:24px;\"\u003e\n    \u003cdiv style=\"flex:1; min-width:240px; background:#f8f9fa; border-left:4px solid #333; padding:16px 20px; border-radius:4px;\"\u003e\n      \u003cp style=\"font-weight:bold; color:#333333; margin:0 0 8px 0;\"\u003eCoverage Footprint\u003c\/p\u003e\n      \u003cul style=\"margin:0; padding-left:18px; color:#000000;\"\u003e\n        \u003cli\u003eVegetative: 4×5 ft\u003c\/li\u003e\n        \u003cli\u003eFlowering: 3×5 ft\u003c\/li\u003e\n        \u003cli\u003eRecommended space: 4×2×6 ft enclosure or equivalent open room bay\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1; min-width:240px; background:#f8f9fa; border-left:4px solid #333; padding:16px 20px; border-radius:4px;\"\u003e\n      \u003cp style=\"font-weight:bold; color:#333333; margin:0 0 8px 0;\"\u003eSuitable Deployment Environments\u003c\/p\u003e\n      \u003cul style=\"margin:0; padding-left:18px; color:#000000;\"\u003e\n        \u003cli\u003eLicensed indoor cultivation rooms with controlled temperature and humidity\u003c\/li\u003e\n        \u003cli\u003eMulti-tier vertical production bays where bar-style geometry reduces inter-canopy shadowing\u003c\/li\u003e\n        \u003cli\u003eGreenhouse supplemental lighting installations requiring broadband spectral coverage\u003c\/li\u003e\n        \u003cli\u003eFacilities scaling from single-unit pilots to networked 60-unit arrays via daisy-chain\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n    \u003cdiv style=\"flex:1; min-width:240px; background:#f8f9fa; border-left:4px solid #333; padding:16px 20px; border-radius:4px;\"\u003e\n      \u003cp style=\"font-weight:bold; color:#333333; margin:0 0 8px 0;\"\u003eNot Recommended For\u003c\/p\u003e\n      \u003cul style=\"margin:0; padding-left:18px; color:#000000;\"\u003e\n        \u003cli\u003eEnvironments exceeding 40°C ambient operating temperature without supplemental cooling\u003c\/li\u003e\n        \u003cli\u003eApplications requiring UV-specific or far-red-specific single-channel spectral control\u003c\/li\u003e\n        \u003cli\u003eInstallations where input voltage falls outside the 100–277V range\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c!-- SECTION 4: CORE MECHANISM --\u003e\n\u003cdiv style=\"margin:36px 0;\"\u003e\n  \u003ch2 style=\"color:#333333; font-size:1.5em; margin-bottom:12px;\"\u003eHow It Works\u003c\/h2\u003e\n\n  \u003cp style=\"color:#000000; margin-bottom:18px;\"\u003eThe SP-6500 is built around the Samsung LM301H EVO diode — a high-efficacy emitter that achieves up to 2.8 µmol\/J photosynthetic photon efficacy at the fixture level. The bar-style PCB layout distributes emitters across a 42.1\"×3.5\"×3.6\" (107×9×9.2 cm) form factor, producing a wide, even photon distribution that minimizes shadow cast and reduces the edge-falloff variance that panel-style fixtures introduce at equivalent wattages. The sunlike full-spectrum output covers the broadband range required for both vegetative and reproductive growth phases without requiring spectral channel switching between cycles.\u003c\/p\u003e\n\n  \u003cp style=\"color:#000000; margin-bottom:18px;\"\u003eThermal management is entirely passive. There are no fans, no moving parts, and no active cooling components to maintain or replace. Heat is dissipated through the aluminum bar housing, keeping the fixture surface within operational limits at ambient temperatures up to 40°C. This architecture eliminates the noise, vibration, and maintenance overhead associated with active-cooling fixtures while reducing the HVAC sensible heat load contribution from the fixture itself.\u003c\/p\u003e\n\n  \u003cp style=\"color:#000000; margin-bottom:18px;\"\u003eDimming is executed through a dedicated control panel that includes a DIM switch, CH1 and CH2 RJ11 ports, a dimmer knob, an EXT switch, and an OFF switch. The 10%–100% dimming range allows precise intensity calibration across growth stages without requiring external controllers for basic operation. For multi-room or multi-tier deployments, the daisy-chain architecture supports up to 60 units per control network, enabling centralized scheduling and intensity management at scale. Input power is 650W ±5% across a 100–277V universal voltage range, drawing 5.404A at AC120V, 2.662A at AC240V, or 2.311A at AC277V — compatible with standard North American and international commercial electrical infrastructure. In practical terms, the SP-6500 delivers up to 2.8 µmol\/J efficacy across a 3×5 ft flowering footprint at 650W ±5% with fully passive thermal management and a 60-unit daisy-chain control capacity.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- SECTION 5: CONFIGURATION DECODER — SINGLE VARIANT, SKIP --\u003e\n\n\u003c!-- SECTION 6: COMMERCIAL ASSURANCE --\u003e\n\u003cdiv style=\"background:#f0f7ff; border-left:4px solid #007bff; padding:20px 24px; margin:36px 0; border-radius:4px;\"\u003e\n  \u003ch2 style=\"color:#333333; font-size:1.4em; margin-bottom:12px;\"\u003eCommercial Assurance\u003c\/h2\u003e\n  \u003cp style=\"color:#000000; margin-bottom:12px;\"\u003eThe SP-6500 is sold through Cannafull Spectrum Solutions as a factory-authorized dealer. Every unit ships with full manufacturer warranty coverage and is backed by the Mars Hydro two-tier service structure.\u003c\/p\u003e\n  \u003cul style=\"margin:0; padding-left:20px; color:#000000;\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWarranty Period:\u003c\/strong\u003e 5 years from date of purchase\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eYear 1 Coverage:\u003c\/strong\u003e Free repair and return shipping — no cost to the operator\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eYears 2–5 Coverage:\u003c\/strong\u003e Component parts covered by manufacturer; operator responsible for shipping, labor, and handling costs\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e ETL (Intertek), HASL, RoHS, CE, UK\/CA — verified for deployment in licensed U.S. commercial facilities\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRecyclable Product:\u003c\/strong\u003e Fixture qualifies under recyclable product designation per certification documentation\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAuthorized Channel:\u003c\/strong\u003e Purchasing through Cannafull Spectrum Solutions preserves full warranty eligibility; gray-market units may not qualify for manufacturer service\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003c!-- SECTION 7: SYSTEM INTEGRATION --\u003e\n\u003cdiv style=\"margin:36px 0;\"\u003e\n  \u003ch2 style=\"color:#333333; font-size:1.5em; margin-bottom:12px;\"\u003eSystem Integration\u003c\/h2\u003e\n  \u003cul style=\"color:#000000; padding-left:20px;\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eVoltage Compatibility:\u003c\/strong\u003e Universal 100–277V input accepts standard U.S. commercial 120V and 240V circuits as well as 277V single-phase industrial feeds without adapters or step-down transformers\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eNetwork Scalability:\u003c\/strong\u003e CH1\/CH2 RJ11 daisy-chain ports support up to 60 units per control network, enabling centralized dimming and scheduling across multi-room deployments from a single dimmer knob or EXT controller input\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePassive Thermal Profile:\u003c\/strong\u003e No active cooling components means zero fan noise, zero vibration, and no fan-motor maintenance intervals; fixture thermal output must be included in room-level HVAC load calculations\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Steel hanger and YoYo included; bar-style geometry is compatible with standard overhead racking and adjustable suspension systems in 4×2×6 ft and larger enclosures\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eElectrical Draw Reference:\u003c\/strong\u003e At AC120V, each unit draws 5.404A; plan circuit loading at no more than 80% of breaker capacity per NEC guidelines when sizing dedicated circuits for multi-unit arrays\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003c!-- SECTION 8: FACILITY INTEGRATION DATA --\u003e\n\u003cdiv style=\"background:#f0f7ff; border-left:4px solid #007bff; padding:20px 24px; margin:36px 0; border-radius:4px;\"\u003e\n  \u003ch3 style=\"color:#333333; font-size:1.3em; margin-bottom:10px;\"\u003eFacility Integration Data\u003c\/h3\u003e\n  \u003cp style=\"color:#000000; margin-bottom:16px;\"\u003eUse the table below to project electrical load and capital outlay when scaling SP-6500 deployments across a licensed facility. All figures are based on 650W ±5% per unit at AC120V draw of 5.404A; actual energy costs will vary by utility rate and operational photoperiod.\u003c\/p\u003e\n  \u003ctable style=\"width:100%; border-collapse:collapse; color:#000000; font-size:0.95em;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"background:#007bff; color:#ffffff;\"\u003e\n        \u003cth style=\"padding:10px 12px; text-align:left; border:1px solid #cce0ff;\"\u003eFleet Size\u003c\/th\u003e\n        \u003cth style=\"padding:10px 12px; text-align:left; border:1px solid #cce0ff;\"\u003eTotal Input Power (W)\u003c\/th\u003e\n        \u003cth style=\"padding:10px 12px; text-align:left; border:1px solid #cce0ff;\"\u003eTotal Current @AC120V (A)\u003c\/th\u003e\n        \u003cth style=\"padding:10px 12px; text-align:left; border:1px solid #cce0ff;\"\u003eTotal Flowering Coverage\u003c\/th\u003e\n        \u003cth style=\"padding:10px 12px; text-align:left; border:1px solid #cce0ff;\"\u003eCapital Outlay (MAP $599.99\/unit)\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background:#ffffff;\"\u003e\n        \u003ctd style=\"padding:9px 12px; border:1px solid #cce0ff;\"\u003e10 Units\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px; border:1px solid #cce0ff;\"\u003e6,500W\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px; border:1px solid #cce0ff;\"\u003e54.04A\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px; border:1px solid #cce0ff;\"\u003e150 sq ft (10 × 3×5 ft)\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px; border:1px solid #cce0ff;\"\u003e$5,999.90\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0f7ff;\"\u003e\n        \u003ctd style=\"padding:9px 12px; border:1px solid #cce0ff;\"\u003e20 Units\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px; border:1px solid #cce0ff;\"\u003e13,000W\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px; border:1px solid #cce0ff;\"\u003e108.08A\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px; border:1px solid #cce0ff;\"\u003e300 sq ft (20 × 3×5 ft)\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px; border:1px solid #cce0ff;\"\u003e$11,999.80\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#ffffff;\"\u003e\n        \u003ctd style=\"padding:9px 12px; border:1px solid #cce0ff;\"\u003e50 Units\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px; border:1px solid #cce0ff;\"\u003e32,500W\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px; border:1px solid #cce0ff;\"\u003e270.20A\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px; border:1px solid #cce0ff;\"\u003e750 sq ft (50 × 3×5 ft)\u003c\/td\u003e\n        \u003ctd style=\"padding:9px 12px; border:1px solid #cce0ff;\"\u003e$29,999.50\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n  \u003cp style=\"font-size:0.85em; color:#666; margin-top:10px;\"\u003eCircuit sizing must comply with NEC 80% continuous load rule. Consult a licensed electrician before finalizing panel and breaker specifications for any multi-unit array. Capital outlay figures are based on MAP pricing of $599.99 per unit and do not include shipping, installation, or ancillary infrastructure costs.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- SECTION 9: OPERATOR FIELD NOTE --\u003e\n\u003cdiv style=\"margin:36px 0;\"\u003e\n  \u003ch2 style=\"color:#333333; font-size:1.5em; margin-bottom:12px;\"\u003eOperator Field Note\u003c\/h2\u003e\n  \u003cul style=\"color:#000000; padding-left:20px;\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDimming dead zones are eliminated:\u003c\/strong\u003e The 10%–100% range with dedicated RJ11 ports means intensity transitions between propagation, vegetative, and flowering phases are executed through the control panel, not by repositioning the fixture or swapping hardware\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePassive cooling changes the maintenance calculus:\u003c\/strong\u003e No fan bearings to replace, no airflow channels to clean, no noise floor contribution to the room — the fixture's only scheduled maintenance is periodic lens and bar surface cleaning\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eThe daisy-chain limit of 60 units is a practical ceiling for most craft-scale rooms:\u003c\/strong\u003e At 3×5 ft per unit, 60 fixtures cover 900 sq ft of flowering canopy — sufficient for most licensed single-room or two-room operations without requiring a secondary control network\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eVoltage flexibility reduces infrastructure cost:\u003c\/strong\u003e The 100–277V universal input means the SP-6500 can be deployed on existing 120V circuits or upgraded 240V\/277V feeds without purchasing voltage-specific SKUs or step-down transformers\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWeight and dimensions support standard racking:\u003c\/strong\u003e At 17.3 LB (7.8 KG) and 42.1\"×3.5\"×3.6\", the fixture fits standard overhead suspension systems and does not require reinforced mounting hardware in most commercial grow room configurations\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eETL certification is the compliance baseline:\u003c\/strong\u003e ETL listing through Intertek satisfies the electrical safety documentation requirements of most licensed facility inspections across the contiguous United States — confirm jurisdiction-specific requirements with your compliance officer before installation\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003c!-- SECTION 10: OPERATOR FAQ --\u003e\n\u003cdiv style=\"margin:36px 0;\" itemscope itemtype=\"https:\/\/schema.org\/FAQPage\"\u003e\n  \u003ch2 style=\"color:#333333; font-size:1.5em; margin-bottom:16px;\"\u003eOperator FAQ\u003c\/h2\u003e\n\n  \u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"margin-bottom:12px; border:1px solid #ddd; border-radius:4px; padding:12px 16px;\"\u003e\n    \u003csummary itemprop=\"name\" style=\"font-weight:bold; color:#333333; cursor:pointer;\"\u003eQ: What is the exact current draw of the SP-6500 at each supported voltage?\u003c\/summary\u003e\n    \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n      \u003cp itemprop=\"text\" style=\"color:#000000; margin-top:10px;\"\u003eA: The SP-6500 draws 5.404A at AC120V, 2.662A at AC240V, and 2.311A at AC277V. Input power is 650W ±5% across all voltage configurations. When sizing circuits, apply the NEC 80% continuous load rule — a single unit on a 120V circuit requires a minimum 7A-rated circuit, and multi-unit arrays must be calculated accordingly by a licensed electrician.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"margin-bottom:12px; border:1px solid #ddd; border-radius:4px; padding:12px 16px;\"\u003e\n    \u003csummary itemprop=\"name\" style=\"font-weight:bold; color:#333333; cursor:pointer;\"\u003eQ: How many SP-6500 units can be networked together on a single daisy-chain control run?\u003c\/summary\u003e\n    \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n      \u003cp itemprop=\"text\" style=\"color:#000000; margin-top:10px;\"\u003eA: Up to 60 units can be connected per daisy-chain network using the CH1 and CH2 RJ11 ports on the dimmer control panel. All 60 units respond to a single dimmer knob or EXT controller input, enabling centralized intensity management across a 900 sq ft flowering canopy (at 3×5 ft per unit) without additional control hardware.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"margin-bottom:12px; border:1px solid #ddd; border-radius:4px; padding:12px 16px;\"\u003e\n    \u003csummary itemprop=\"name\" style=\"font-weight:bold; color:#333333; cursor:pointer;\"\u003eQ: What is the coverage area difference between vegetative and flowering configurations?\u003c\/summary\u003e\n    \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n      \u003cp itemprop=\"text\" style=\"color:#000000; margin-top:10px;\"\u003eA: The SP-6500 covers 4×5 ft (20 sq ft) in vegetative mode and 3×5 ft (15 sq ft) in flowering mode. The reduced flowering footprint reflects the higher PPFD density required during the reproductive phase. Operators running continuous-light or mixed-phase rooms should plan fixture spacing based on the flowering footprint to ensure adequate intensity at canopy level during the most photon-demanding growth stage.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"margin-bottom:12px; border:1px solid #ddd; border-radius:4px; padding:12px 16px;\"\u003e\n    \u003csummary itemprop=\"name\" style=\"font-weight:bold; color:#333333; cursor:pointer;\"\u003eQ: Does the SP-6500 require active cooling or supplemental airflow directed at the fixture?\u003c\/summary\u003e\n    \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n      \u003cp itemprop=\"text\" style=\"color:#000000; margin-top:10px;\"\u003eA: No. The SP-6500 uses fully passive thermal management — heat is dissipated through the aluminum bar housing with no fans, no moving parts, and no active cooling components. The maximum operating temperature is 40°C ambient. While no airflow is required at the fixture itself, room-level HVAC must account for the total sensible heat load of the fixture array. Consult your mechanical engineer for room-level thermal calculations.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"margin-bottom:12px; border:1px solid #ddd; border-radius:4px; padding:12px 16px;\"\u003e\n    \u003csummary itemprop=\"name\" style=\"font-weight:bold; color:#333333; cursor:pointer;\"\u003eQ: What does the two-tier warranty structure cover, and how does it differ between Year 1 and Years 2–5?\u003c\/summary\u003e\n    \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n      \u003cp itemprop=\"text\" style=\"color:#000000; margin-top:10px;\"\u003eA: During Year 1, Mars Hydro covers both repair costs and return shipping at no charge to the operator. From Years 2 through 5, the manufacturer covers component parts, but the operator is responsible for shipping, labor, and handling costs. The full 5-year warranty period begins from the date of purchase. Purchasing through Cannafull Spectrum Solutions as a factory-authorized dealer preserves full warranty eligibility.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"margin-bottom:12px; border:1px solid #ddd; border-radius:4px; padding:12px 16px;\"\u003e\n    \u003csummary itemprop=\"name\" style=\"font-weight:bold; color:#333333; cursor:pointer;\"\u003eQ: Which certifications does the SP-6500 carry, and are they sufficient for licensed facility inspections in the United States?\u003c\/summary\u003e\n    \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n      \u003cp itemprop=\"text\" style=\"color:#000000; margin-top:10px;\"\u003eA: The SP-6500 carries ETL listing through Intertek, HASL, RoHS, CE, UK\/CA certification, and Recyclable Product designation. ETL listing is the primary electrical safety credential recognized by AHJs (Authorities Having Jurisdiction) across licensed U.S. facilities. RoHS compliance addresses hazardous substance restrictions. Operators should confirm jurisdiction-specific inspection requirements with their compliance officer, as state and local licensing bodies may have additional documentation requirements beyond ETL listing.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/details\u003e\n\u003c\/div\u003e\n\n\u003c!-- SECTION 11: SHIPPING \u0026 LOGISTICS --\u003e\n\u003cdiv style=\"margin:36px 0;\"\u003e\n  \u003ch2 style=\"color:#333333; font-size:1.5em; margin-bottom:12px;\"\u003eShipping \u0026amp; Logistics\u003c\/h2\u003e\n  \u003cul style=\"color:#000000; padding-left:20px;\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eShipping Territory:\u003c\/strong\u003e Cannafull Spectrum Solutions ships within the contiguous 48 United States only. Orders to Alaska, Hawaii, U.S. territories, and international destinations cannot be fulfilled through this channel.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eLead Time:\u003c\/strong\u003e In-stock units typically ship within 1–3 business days. Multi-unit fleet orders (10+ units) may require additional processing time; contact Cannafull Spectrum Solutions prior to placing large-quantity orders to confirm availability and lead time.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eReturns:\u003c\/strong\u003e Returns are accepted in accordance with the Cannafull Spectrum Solutions Return Policy. Defective units are handled under the Mars Hydro two-tier warranty structure. Non-defective returns must be initiated within the return window specified in the Return Policy and must be in original, uninstalled condition.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRestocking Fee:\u003c\/strong\u003e Returns of non-defective items are subject to a restocking fee of up to 25% per our Return Policy. Review full terms at cannafullspec.com\/pages\/return-policy before ordering.\u003c\/li\u003e\n  \u003c\/ul\u003e\n  \u003cp style=\"font-weight:bold; color:#333333; margin-top:14px;\"\u003eFor fleet pricing, volume availability, or pre-purchase technical consultation: contact Cannafull Spectrum Solutions directly before placing your order.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- SECTION 12: WHAT'S IN THE BOX --\u003e\n\u003cdiv style=\"margin:36px 0;\"\u003e\n  \u003ch2 style=\"color:#333333; font-size:1.5em; margin-bottom:12px;\"\u003eWhat's in the Box\u003c\/h2\u003e\n  \u003cul style=\"color:#000000; padding-left:20px;\"\u003e\n    \u003cli\u003e1× Mars Hydro SP-6500 LED Grow Light\u003c\/li\u003e\n    \u003cli\u003e1× Power Cord\u003c\/li\u003e\n    \u003cli\u003e1× YoYo (adjustable suspension)\u003c\/li\u003e\n    \u003cli\u003e1× Steel Hanger\u003c\/li\u003e\n    \u003cli\u003e1× Dimming Cable (included with SP-6500; not included with SP-150)\u003c\/li\u003e\n  \u003c\/ul\u003e\n  \u003cp style=\"font-size:0.85em; color:#666; margin-top:10px;\"\u003eIncluded items are confirmed from manufacturer source documentation. Cannafull Spectrum Solutions does not modify, repackage, or substitute kit contents. If your shipment is missing any listed item, contact us within 48 hours of delivery with your order number and photographic documentation of the received contents.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- SECTION 13: REGIONAL COMPLIANCE \u0026 DEPLOYMENT NOTES --\u003e\n\u003cdiv style=\"margin:36px 0;\"\u003e\n  \u003ch2 style=\"color:#333333; font-size:1.5em; margin-bottom:12px;\"\u003eRegional Compliance \u0026amp; Deployment Notes\u003c\/h2\u003e\n  \u003cul style=\"color:#000000; padding-left:20px;\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eElectrical Safety Listing:\u003c\/strong\u003e The SP-6500 carries ETL listing through Intertek, which is recognized by Authorities Having Jurisdiction (AHJs) across licensed cultivation facilities in the contiguous United States. ETL listing satisfies the electrical safety documentation baseline for most state-level cannabis facility inspections.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRoHS Compliance:\u003c\/strong\u003e The fixture meets RoHS (Restriction of Hazardous Substances) requirements, relevant for facilities operating under environmental compliance frameworks or seeking green building certifications.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCE and UK\/CA Certification:\u003c\/strong\u003e CE and UK\/CA markings are present on the fixture. These certifications apply to European and UK\/Canadian market requirements and are noted for informational purposes; Cannafull Spectrum Solutions deploys this product exclusively within the contiguous 48 United States.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRecyclable Product Designation:\u003c\/strong\u003e The SP-6500 qualifies under the Recyclable Product designation per its certification documentation, supporting end-of-life disposal compliance in jurisdictions with electronic waste regulations.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eNEC Compliance Responsibility:\u003c\/strong\u003e Electrical installation must comply with the National Electrical Code (NEC) and all applicable local amendments. Circuit sizing, breaker selection, and grounding must be performed or verified by a licensed electrician. Cannafull Spectrum Solutions and Mars Hydro are not responsible for installation errors or code violations arising from improper electrical work.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eState Licensing Variability:\u003c\/strong\u003e Licensed cultivation facility requirements vary by state. Operators in regulated markets should confirm that fixture specifications, certifications, and installation documentation satisfy their specific state licensing body's requirements prior to installation.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"font-size:0.85em; color:#666;\"\u003eCompliance information is provided for reference only and does not constitute legal or regulatory advice. Requirements vary by jurisdiction and are subject to change. Operators are responsible for verifying current applicable standards with their licensed electrician, compliance officer, and state regulatory authority prior to installation and facility inspection.\u003c\/p\u003e","brand":"Mars Hydro","offers":[{"title":"Default Title","offer_id":44237274316935,"sku":"MH-SP-6500","price":599.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/4450\/4455\/files\/mars_hydro_sp3000_led_with_professional_grade_performance_f530dcbb-b27d-4661-8b20-34e4f1dadbf9.jpg?v=1774169688","url":"https:\/\/cannafullspec.com\/es\/products\/mars-hydro-sp-6500-650w-commercial-led","provider":"CannaFull Spectrum Solutions","version":"1.0","type":"link"}