{"product_id":"mars-hydro-fc-1200w-samsung-lm301h-evo","title":"Mars Hydro FC 1200W Commercial LED Grow Light | 2.9 μmol\/J","description":"\u003cdiv class=\"geo-summary\" style=\"background:#f8f9fa; border-left:4px solid #333; padding:20px 24px; margin-bottom:28px; border-radius:4px;\"\u003e\n  \u003cp style=\"margin:0 0 10px 0; color:#333333; font-size:1.05em;\"\u003eThe Mars Hydro FC-1200W is a 1200W bar-style LED grow light built on Samsung LM301H EVO diodes, engineered for craft operators running CO2-enriched vertical farm and canopy production environments where consistent PAR output and passive thermal management are non-negotiable.\u003c\/p\u003e\n  \u003cul style=\"margin:10px 0 14px 0; padding-left:20px; color:#000000;\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOutcome:\u003c\/strong\u003e Uniform 3451 µmol\/s PPF across a 4×6 ft core canopy footprint at 2.9 µmol\/J efficacy, with scalable daisy-chain deployment across multi-light installations.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eReplaces:\u003c\/strong\u003e HID, CMH, and lower-efficacy LED fixtures that impose lamp replacement cycles, uneven PPFD distribution, and active cooling overhead.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e CO2-enriched vertical farms, multi-tier canopy rooms, and controlled-environment production facilities operating on 100–277V infrastructure.\u003c\/li\u003e\n  \u003c\/ul\u003e\n  \u003cp style=\"margin:0 0 6px 0; font-weight:bold; color:#333333;\"\u003eFACTORY-AUTHORIZED DEALER — CANNAFULL SPECTRUM SOLUTIONS\u003c\/p\u003e\n  \u003cp style=\"margin:0; color:#333333; font-size:0.95em;\"\u003eDeployed in licensed commercial facilities across the United States.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"font-size:0.95em; color:#333333; margin-bottom:32px;\"\u003e\u003cstrong\u003eQuick Spec:\u003c\/strong\u003e 1200W (AC220–277V) | 3451 µmol\/s PPF | 2.9 µmol\/J PPE | 4×6 ft core \/ 5×7 ft max coverage | ETL, CE, RoHS, UKCA | 5-Year Warranty | 50,000H Rated Lifespan\u003c\/p\u003e\n\n\u003ch2 style=\"text-align:center; color:#333333; font-size:1.75em; margin-bottom:20px;\"\u003ePrecision Control in Any Space\u003c\/h2\u003e\n\n\u003cp style=\"color:#000000; margin-bottom:18px;\"\u003eEvery facility running inconsistent lighting equipment is paying a tax it cannot see on the balance sheet. Uneven canopy coverage means the plants at the perimeter of your footprint are operating at a different DLI than those at center — and that variance compounds across every cycle. Equipment that requires manual intervention to maintain output, fixtures that degrade in efficacy as lamp hours accumulate, and thermal loads that force HVAC systems to compensate for heat that should never have been generated in the first place: these are the operational failure modes that quietly erode margin, inflate utility costs, and introduce batch-to-batch inconsistency that no post-harvest protocol can fully correct.\u003c\/p\u003e\n\n\u003cp style=\"color:#000000; margin-bottom:18px;\"\u003eAfter deployment, the production environment changes in measurable ways. The canopy receives uniform photon density from edge to edge, eliminating the spatial variance that forces operators to rotate plants or accept uneven development across a bench. Scheduling runs through a programmable control architecture that removes manual adjustment from the daily workflow. There are no lamp replacement cycles to budget for, no re-lamping downtime to schedule, and no efficacy cliff at 10,000 hours that forces a premature fixture swap. The facility operates on a known, repeatable photon budget — and that predictability is the foundation of consistent yield output.\u003c\/p\u003e\n\n\u003cp style=\"color:#000000; margin-bottom:18px;\"\u003eThe mechanism behind that outcome is a nine-bar passive-cooled array driven entirely by Samsung LM301H EVO diodes — the same diode architecture used in premium-tier commercial fixtures — paired with a full-spectrum output spanning 660–665nm red, 2800–3000K warm white, and 4800–5000K cool white channels. At AC220–277V, the fixture draws 1200W (±5%) and produces 3451 µmol\/s PPF at a photon efficacy of 2.9 µmol\/J. The passive thermal design eliminates fan assemblies, removing the primary mechanical failure point in active-cooled fixtures and reducing audible noise output to zero. Core coverage is rated at 4×6 ft with a maximum canopy footprint of 5×7 ft, and the foldable bar design supports flat-pack shipping and rapid deployment without specialized tooling. In practical terms, the FC-1200W delivers 3451 µmol\/s PPF across a 4×6 ft core footprint at 1200W draw on 220–277V infrastructure, with a rated lifespan of 50,000 hours and a 5-year manufacturer warranty.\u003c\/p\u003e\n\n\u003chr style=\"border:none; border-top:1px solid #e0e0e0; margin:32px 0;\"\u003e\n\n\u003ch2 style=\"color:#333333; font-size:1.45em; margin-bottom:14px;\"\u003eWhere This Belongs (and Doesn't)\u003c\/h2\u003e\n\n\u003cp style=\"font-style:italic; color:#555555; margin-bottom:18px; font-size:0.92em;\"\u003eElectrical infrastructure must be verified by a licensed electrician prior to installation. HVAC load calculations should account for the fixture's 4,094 BTU\/hr thermal output. Cannafull Spectrum Solutions does not provide electrical or mechanical engineering services.\u003c\/p\u003e\n\n\u003cdiv style=\"display:flex; gap:24px; flex-wrap:wrap; margin-bottom:10px;\"\u003e\n  \u003cdiv style=\"flex:1; min-width:220px; background:#f8f9fa; border-left:4px solid #333; padding:16px 18px; border-radius:4px;\"\u003e\n    \u003cp style=\"font-weight:bold; color:#333333; margin:0 0 8px 0;\"\u003eCoverage Area\u003c\/p\u003e\n    \u003cul style=\"margin:0; padding-left:18px; color:#000000; font-size:0.95em;\"\u003e\n      \u003cli\u003e\n\u003cstrong\u003eVegetative (Core):\u003c\/strong\u003e 4×6 ft\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eFlower (Max):\u003c\/strong\u003e 5×7 ft\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eRecommended Tent:\u003c\/strong\u003e 4×8 ft\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"flex:2; min-width:280px; color:#000000; font-size:0.95em;\"\u003e\n    \u003cp style=\"font-weight:bold; color:#333333; margin:0 0 8px 0;\"\u003eDeployment Fit\u003c\/p\u003e\n    \u003cul style=\"margin:0; padding-left:18px;\"\u003e\n      \u003cli\u003e\n\u003cstrong\u003eDesigned for:\u003c\/strong\u003e CO2-enriched vertical farms, multi-tier canopy rooms, controlled-environment production bays, and scalable multi-light installations using daisy-chain control.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eRequires:\u003c\/strong\u003e AC100–277V supply; 220–277V recommended for full 1200W output. Adequate overhead clearance for bar-style mounting. Passive cooling relies on ambient airflow — do not enclose fixture in sealed cavities without ventilation.\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eNot suited for:\u003c\/strong\u003e Installations where active cooling is mandated by facility code, or environments where ambient temperatures consistently exceed manufacturer thermal ratings.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003chr style=\"border:none; border-top:1px solid #e0e0e0; margin:32px 0;\"\u003e\n\n\u003ch2 style=\"color:#333333; font-size:1.45em; margin-bottom:14px;\"\u003eHow It Works\u003c\/h2\u003e\n\n\u003cp style=\"color:#000000; margin-bottom:18px;\"\u003eThe FC-1200W is built around a nine-bar passive-cooled architecture in which each bar houses a dense array of Samsung LM301H EVO diodes — a third-generation high-efficacy chip that delivers industry-leading photon output per watt of electrical input. The diode array produces a full-spectrum output combining 660–665nm deep red for photosynthetic peak absorption, 2800–3000K warm white for broad-spectrum vegetative and reproductive support, and 4800–5000K cool white for blue-channel canopy penetration and structural development. All three spectral channels operate simultaneously across the full 9-bar array, producing a blended output that covers the 350–750nm photosynthetically active range without spectral gaps.\u003c\/p\u003e\n\n\u003cp style=\"color:#000000; margin-bottom:18px;\"\u003eThermal management is entirely passive. The bar-style aluminum substrate conducts heat away from the diode junction and dissipates it across the fixture's surface area without fans, pumps, or any moving mechanical components. This architecture eliminates the primary failure mode of active-cooled fixtures — fan bearing degradation — and contributes directly to the fixture's 50,000-hour rated lifespan. The foldable bar design allows the fixture to ship flat, reducing freight damage risk and enabling rapid deployment: bars unfold and lock into operating position without tools, and the fixture is ready for hang and power-on in a single workflow step.\u003c\/p\u003e\n\n\u003cp style=\"color:#000000; margin-bottom:18px;\"\u003eAt AC220–277V, the fixture operates at 1200W (±5%), drawing 3.266A at 240V or 2.847A at 277V. At AC100–120V, wattage steps down to 840W (±5%) with a 6.635A draw at 120V. PPF output is 3451 µmol\/s at a photon efficacy of 2.9 µmol\/J. The fixture is rated for a maximum yield of 3.5 g\/W under optimized CO2-enriched conditions. Thermal output is 4,094 BTU\/hr, which must be factored into facility HVAC load calculations. Physical dimensions are 66×45×3.8 inches in operating configuration. Certifications include ETL, CE, RoHS, and UKCA, covering U.S. and international market compliance. In practical terms, the FC-1200W delivers 3451 µmol\/s PPF at 2.9 µmol\/J across a 4×6 ft core canopy footprint at 1200W on 220–277V, with a 50,000-hour passive-cooled lifespan and no scheduled lamp replacement intervals.\u003c\/p\u003e\n\n\u003chr style=\"border:none; border-top:1px solid #e0e0e0; margin:32px 0;\"\u003e\n\n\u003cdiv style=\"background:#f0f7ff; border-left:4px solid #007bff; padding:20px 24px; margin-bottom:28px; border-radius:4px;\"\u003e\n  \u003ch2 style=\"color:#333333; font-size:1.35em; margin:0 0 12px 0;\"\u003eCommercial Assurance\u003c\/h2\u003e\n  \u003cul style=\"margin:0; padding-left:20px; color:#000000; font-size:0.95em;\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 5-year manufacturer warranty on the FC-1200W (MH-FC-1200W). Coverage applies to defects in materials and workmanship under normal operating conditions.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRated Lifespan:\u003c\/strong\u003e 50,000 hours — sourced directly from Table A for this SKU. No cross-SKU inheritance applied.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e ETL (U.S. market), CE, RoHS, UKCA. ETL listing confirms compliance with applicable U.S. electrical safety standards.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAuthorized Channel:\u003c\/strong\u003e Cannafull Spectrum Solutions is a factory-authorized dealer. Warranty is manufacturer-backed and valid for purchases through this channel.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSupport:\u003c\/strong\u003e Contact Cannafull Spectrum Solutions for pre-sale configuration questions, warranty claims, and post-deployment technical support.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003chr style=\"border:none; border-top:1px solid #e0e0e0; margin:32px 0;\"\u003e\n\n\u003ch2 style=\"color:#333333; font-size:1.45em; margin-bottom:14px;\"\u003eSystem Integration\u003c\/h2\u003e\n\n\u003cul style=\"color:#000000; font-size:0.95em; padding-left:20px; margin-bottom:10px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage Compatibility:\u003c\/strong\u003e AC100–277V universal input. Full 1200W output requires AC220–277V supply. Facilities on 120V infrastructure will operate at 840W (±5%) — confirm electrical capacity before specifying fixture count per circuit.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDaisy-Chain Control:\u003c\/strong\u003e The iConnect daisy-chain system allows multiple FC-1200W units to be linked and controlled from a single dimming interface, reducing control wiring complexity in multi-light installations and enabling zone-level scheduling without individual fixture intervention.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThermal Load Planning:\u003c\/strong\u003e Each fixture contributes 4,094 BTU\/hr to the facility thermal load. HVAC sizing must account for cumulative BTU output across all installed units — passive cooling transfers heat to ambient air, which must be actively managed by facility climate systems.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting and Deployment:\u003c\/strong\u003e Foldable bar design ships flat and deploys without tools. Physical dimensions in operating configuration are 66×45×3.8 inches. Confirm overhead clearance and racking geometry before ordering fleet quantities.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCO2 Integration:\u003c\/strong\u003e The fixture is rated for high-PPFD CO2-enriched cultivation environments. At 3451 µmol\/s PPF and 3.5 g\/W maximum yield potential, the FC-1200W is designed to operate alongside supplemental CO2 delivery systems targeting elevated atmospheric CO2 concentrations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr style=\"border:none; border-top:1px solid #e0e0e0; margin:32px 0;\"\u003e\n\n\u003ch3 style=\"color:#333333; font-size:1.3em; margin-bottom:10px;\"\u003eFacility Integration Data\u003c\/h3\u003e\n\n\u003cp style=\"color:#000000; margin-bottom:18px; font-size:0.95em;\"\u003eThe table below provides fleet-level electrical and thermal planning data for licensed operators evaluating the FC-1200W at scale. All values are calculated from verified Table A specifications at AC240V operating voltage.\u003c\/p\u003e\n\n\u003cdiv style=\"background:#f0f7ff; border-left:4px solid #007bff; padding:20px 24px; border-radius:4px; margin-bottom:10px;\"\u003e\n  \u003cp style=\"font-weight:bold; color:#333333; margin:0 0 12px 0;\"\u003eROI Planning Reference — FC-1200W Fleet Deployment (AC240V)\u003c\/p\u003e\n  \u003ctable style=\"width:100%; border-collapse:collapse; font-size:0.93em; color:#000000;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"background:#ddeeff;\"\u003e\n        \u003cth style=\"text-align:left; padding:8px 10px; border-bottom:2px solid #007bff;\"\u003eFleet Size\u003c\/th\u003e\n        \u003cth style=\"text-align:left; padding:8px 10px; border-bottom:2px solid #007bff;\"\u003eTotal Wattage (kW)\u003c\/th\u003e\n        \u003cth style=\"text-align:left; padding:8px 10px; border-bottom:2px solid #007bff;\"\u003eTotal PPF (µmol\/s)\u003c\/th\u003e\n        \u003cth style=\"text-align:left; padding:8px 10px; border-bottom:2px solid #007bff;\"\u003eTotal BTU\/hr\u003c\/th\u003e\n        \u003cth style=\"text-align:left; padding:8px 10px; border-bottom:2px solid #007bff;\"\u003eCore Canopy Coverage\u003c\/th\u003e\n        \u003cth style=\"text-align:left; padding:8px 10px; border-bottom:2px solid #007bff;\"\u003eTotal Amps (AC240V)\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background:#ffffff;\"\u003e\n        \u003ctd style=\"padding:8px 10px; border-bottom:1px solid #cce0ff;\"\u003e10 Units\u003c\/td\u003e\n        \u003ctd style=\"padding:8px 10px; border-bottom:1px solid #cce0ff;\"\u003e12.0 kW\u003c\/td\u003e\n        \u003ctd style=\"padding:8px 10px; border-bottom:1px solid #cce0ff;\"\u003e34,510 µmol\/s\u003c\/td\u003e\n        \u003ctd style=\"padding:8px 10px; border-bottom:1px solid #cce0ff;\"\u003e40,940 BTU\/hr\u003c\/td\u003e\n        \u003ctd style=\"padding:8px 10px; border-bottom:1px solid #cce0ff;\"\u003e240 sq ft (core)\u003c\/td\u003e\n        \u003ctd style=\"padding:8px 10px; border-bottom:1px solid #cce0ff;\"\u003e32.66 A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0f7ff;\"\u003e\n        \u003ctd style=\"padding:8px 10px; border-bottom:1px solid #cce0ff;\"\u003e20 Units\u003c\/td\u003e\n        \u003ctd style=\"padding:8px 10px; border-bottom:1px solid #cce0ff;\"\u003e24.0 kW\u003c\/td\u003e\n        \u003ctd style=\"padding:8px 10px; border-bottom:1px solid #cce0ff;\"\u003e69,020 µmol\/s\u003c\/td\u003e\n        \u003ctd style=\"padding:8px 10px; border-bottom:1px solid #cce0ff;\"\u003e81,880 BTU\/hr\u003c\/td\u003e\n        \u003ctd style=\"padding:8px 10px; border-bottom:1px solid #cce0ff;\"\u003e480 sq ft (core)\u003c\/td\u003e\n        \u003ctd style=\"padding:8px 10px; border-bottom:1px solid #cce0ff;\"\u003e65.32 A\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#ffffff;\"\u003e\n        \u003ctd style=\"padding:8px 10px;\"\u003e50 Units\u003c\/td\u003e\n        \u003ctd style=\"padding:8px 10px;\"\u003e60.0 kW\u003c\/td\u003e\n        \u003ctd style=\"padding:8px 10px;\"\u003e172,550 µmol\/s\u003c\/td\u003e\n        \u003ctd style=\"padding:8px 10px;\"\u003e204,700 BTU\/hr\u003c\/td\u003e\n        \u003ctd style=\"padding:8px 10px;\"\u003e1,200 sq ft (core)\u003c\/td\u003e\n        \u003ctd style=\"padding:8px 10px;\"\u003e163.30 A\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n  \u003cp style=\"font-size:0.82em; color:#555555; margin:10px 0 0 0;\"\u003eValues calculated at 1200W per unit (AC240V, 3.266A per unit). BTU\/hr based on 4,094 BTU\/hr per fixture. Core coverage based on 4×6 ft (24 sq ft) per unit. Consult a licensed electrician for circuit design and load balancing. HVAC sizing must be performed by a qualified mechanical engineer.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003chr style=\"border:none; border-top:1px solid #e0e0e0; margin:32px 0;\"\u003e\n\n\u003ch2 style=\"color:#333333; font-size:1.45em; margin-bottom:14px;\"\u003eOperator Field Notes\u003c\/h2\u003e\n\n\u003cul style=\"color:#000000; font-size:0.95em; padding-left:20px; margin-bottom:10px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVoltage Selection Is a Yield Decision:\u003c\/strong\u003e Operating at AC100–120V reduces fixture wattage to 840W (±5%) — a 30% reduction in photon output relative to the 1200W rating. Facilities targeting the 3451 µmol\/s PPF specification must supply AC220–277V. Confirm panel capacity and circuit breaker ratings before installation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePassive Cooling Requires Airflow:\u003c\/strong\u003e The passive thermal design depends on ambient air movement across the bar surfaces. In sealed or low-circulation environments, heat accumulation at the fixture can reduce diode junction efficiency and accelerate lumen depreciation. Maintain adequate airflow across the canopy plane.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDaisy-Chain Scaling Has a Practical Limit:\u003c\/strong\u003e The iConnect system supports multi-unit daisy-chain control, but chain length should be validated against the control interface's rated load capacity before deployment. Consult the manufacturer's iConnect documentation for maximum chain configuration.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCO2 Enrichment Unlocks Maximum Yield Potential:\u003c\/strong\u003e The 3.5 g\/W maximum yield figure is rated under CO2-enriched conditions. Facilities not running supplemental CO2 should calibrate yield expectations accordingly — the fixture will still deliver full PPF output, but the biological ceiling for photosynthetic conversion is lower without elevated CO2.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFoldable Design Simplifies Logistics, Not Installation:\u003c\/strong\u003e The flat-pack shipping format reduces freight damage risk and simplifies storage, but the 66×45×3.8-inch operating footprint requires adequate overhead clearance and structural racking capacity. Verify mounting hardware load ratings before fleet deployment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLifespan Is Conditional on Operating Environment:\u003c\/strong\u003e The 50,000-hour rated lifespan assumes operation within manufacturer-specified temperature and humidity ranges. Sustained operation outside those parameters — particularly elevated ambient temperatures — will accelerate lumen depreciation and reduce effective fixture life.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003chr style=\"border:none; border-top:1px solid #e0e0e0; margin:32px 0;\"\u003e\n\n\u003ch2 style=\"color:#333333; font-size:1.45em; margin-bottom:14px;\"\u003eOperator FAQ\u003c\/h2\u003e\n\n\u003cdiv itemscope itemtype=\"https:\/\/schema.org\/FAQPage\"\u003e\n\n  \u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"margin-bottom:14px; border-bottom:1px solid #e0e0e0; padding-bottom:14px;\"\u003e\n    \u003csummary itemprop=\"name\" style=\"font-weight:bold; color:#333333; cursor:pointer; font-size:0.97em;\"\u003eQ: What is the actual wattage of the FC-1200W, and does it change based on input voltage?\u003c\/summary\u003e\n    \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n      \u003cp itemprop=\"text\" style=\"color:#000000; margin:10px 0 0 0; font-size:0.95em;\"\u003eA: Yes — wattage is voltage-dependent. At AC220–277V, the FC-1200W operates at 1200W (±5%), which is the rated specification for PPF, PPE, and maximum yield figures. At AC100–120V, wattage reduces to 840W (±5%). The 3451 µmol\/s PPF and 2.9 µmol\/J PPE values are tied to the 1200W operating point. Facilities on 120V infrastructure will see proportionally reduced photon output.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"margin-bottom:14px; border-bottom:1px solid #e0e0e0; padding-bottom:14px;\"\u003e\n    \u003csummary itemprop=\"name\" style=\"font-weight:bold; color:#333333; cursor:pointer; font-size:0.97em;\"\u003eQ: How does the passive cooling system perform in a high-ambient-temperature grow environment?\u003c\/summary\u003e\n    \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n      \u003cp itemprop=\"text\" style=\"color:#000000; margin:10px 0 0 0; font-size:0.95em;\"\u003eA: Passive cooling transfers heat from the diode junction through the aluminum bar substrate and into the surrounding air. Performance depends on ambient airflow across the fixture surface — in environments with adequate air circulation, the system maintains diode junction temperatures within rated parameters. In sealed or stagnant-air environments, heat accumulation can reduce efficacy and accelerate lumen depreciation. The fixture's 4,094 BTU\/hr thermal output must be managed by facility HVAC systems; passive cooling handles fixture-level thermal management, not room-level climate control.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"margin-bottom:14px; border-bottom:1px solid #e0e0e0; padding-bottom:14px;\"\u003e\n    \u003csummary itemprop=\"name\" style=\"font-weight:bold; color:#333333; cursor:pointer; font-size:0.97em;\"\u003eQ: What does the iConnect daisy-chain system control, and how many units can be linked?\u003c\/summary\u003e\n    \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n      \u003cp itemprop=\"text\" style=\"color:#000000; margin:10px 0 0 0; font-size:0.95em;\"\u003eA: The iConnect system enables multiple FC-1200W fixtures to be linked in a daisy-chain configuration and controlled from a single interface — covering dimming and scheduling functions across all linked units simultaneously. This eliminates the need for individual fixture adjustment in multi-light installations. Maximum chain length should be confirmed against the iConnect controller's rated load capacity as specified in the manufacturer's iConnect documentation before deploying large-scale configurations.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"margin-bottom:14px; border-bottom:1px solid #e0e0e0; padding-bottom:14px;\"\u003e\n    \u003csummary itemprop=\"name\" style=\"font-weight:bold; color:#333333; cursor:pointer; font-size:0.97em;\"\u003eQ: Is the 3.5 g\/W maximum yield achievable without CO2 supplementation?\u003c\/summary\u003e\n    \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n      \u003cp itemprop=\"text\" style=\"color:#000000; margin:10px 0 0 0; font-size:0.95em;\"\u003eA: The 3.5 g\/W maximum yield figure is rated under high-PPFD, CO2-enriched cultivation conditions — the operating environment for which this fixture is specifically designed. Without supplemental CO2, the photosynthetic ceiling is lower regardless of photon availability, and actual yield per watt will fall below the rated maximum. The FC-1200W delivers its full 3451 µmol\/s PPF output in either environment; the yield ceiling is a biological function of CO2 availability, not a fixture limitation.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"margin-bottom:14px; border-bottom:1px solid #e0e0e0; padding-bottom:14px;\"\u003e\n    \u003csummary itemprop=\"name\" style=\"font-weight:bold; color:#333333; cursor:pointer; font-size:0.97em;\"\u003eQ: What certifications does the FC-1200W carry, and are they sufficient for U.S. commercial facility compliance?\u003c\/summary\u003e\n    \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n      \u003cp itemprop=\"text\" style=\"color:#000000; margin:10px 0 0 0; font-size:0.95em;\"\u003eA: The FC-1200W carries ETL, CE, RoHS, and UKCA certifications. ETL listing is the relevant U.S. market certification — it confirms the fixture has been tested and listed by Intertek to applicable U.S. electrical safety standards, which satisfies the electrical safety listing requirement in most U.S. commercial facility codes. CE and UKCA cover European and UK market compliance respectively. Operators should verify specific local AHJ (Authority Having Jurisdiction) requirements, as facility-level compliance obligations vary by state and municipality.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"margin-bottom:14px; padding-bottom:4px;\"\u003e\n    \u003csummary itemprop=\"name\" style=\"font-weight:bold; color:#333333; cursor:pointer; font-size:0.97em;\"\u003eQ: What is the coverage area for vegetative versus flowering stages, and how does mounting height affect PPFD distribution?\u003c\/summary\u003e\n    \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n      \u003cp itemprop=\"text\" style=\"color:#000000; margin:10px 0 0 0; font-size:0.95em;\"\u003eA: Core coverage — the footprint at which the fixture maintains its rated uniform PPFD distribution — is 4×6 ft, which is the recommended vegetative stage footprint. Maximum coverage extends to 5×7 ft and represents the outer boundary for flowering stage deployment where slightly reduced edge PPFD is acceptable. Mounting height directly affects PPFD at canopy level: raising the fixture increases coverage area while reducing PPFD density; lowering it concentrates photon flux over a smaller footprint. For CO2-enriched high-PPFD applications, core coverage at manufacturer-recommended mounting height is the appropriate reference point.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/details\u003e\n\n\u003c\/div\u003e\n\n\u003chr style=\"border:none; border-top:1px solid #e0e0e0; margin:32px 0;\"\u003e\n\n\u003ch2 style=\"color:#333333; font-size:1.45em; margin-bottom:14px;\"\u003eShipping \u0026amp; Logistics\u003c\/h2\u003e\n\n\u003cul style=\"color:#000000; font-size:0.95em; padding-left:20px; margin-bottom:14px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShipping Territory:\u003c\/strong\u003e Cannafull Spectrum Solutions ships within the contiguous 48 United States only. Orders outside this territory cannot be processed through this channel.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFreight Handling:\u003c\/strong\u003e The FC-1200W ships in a flat-pack foldable configuration, reducing freight volume and damage risk during transit. Inspect packaging upon delivery and document any damage before signing the carrier receipt. Freight damage claims must be initiated at time of delivery.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReturns:\u003c\/strong\u003e Returns are accepted for defective units under the manufacturer warranty terms. Non-defective returns are subject to the Cannafull Spectrum Solutions Return Policy. Contact support before initiating any return shipment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRestocking Fee:\u003c\/strong\u003e Returns of non-defective items are subject to a restocking fee of up to 25% per our Return Policy. Review full terms at cannafullspec.com\/pages\/return-policy before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp style=\"color:#333333; font-size:0.95em;\"\u003e\u003cstrong\u003eFor pre-sale configuration support, fleet pricing inquiries, or warranty service: contact Cannafull Spectrum Solutions directly through cannafullspec.com.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003chr style=\"border:none; border-top:1px solid #e0e0e0; margin:32px 0;\"\u003e\n\n\u003ch2 style=\"color:#333333; font-size:1.45em; margin-bottom:14px;\"\u003eWhat's in the Box\u003c\/h2\u003e\n\n\u003cul style=\"color:#000000; font-size:0.95em; padding-left:20px; margin-bottom:14px;\"\u003e\n  \u003cli\u003eMars Hydro FC-1200W LED Grow Light (9-bar array, foldable configuration) — 1 unit\u003c\/li\u003e\n  \u003cli\u003ePower cord (1.6 meters \/ 5.2 feet)\u003c\/li\u003e\n  \u003cli\u003eHanging hardware (ratchet hangers or equivalent mounting hardware as included by manufacturer)\u003c\/li\u003e\n  \u003cli\u003eUser manual \/ quick-start documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp style=\"font-size:0.85em; color:#666666; margin-bottom:10px;\"\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e Box contents are based on available manufacturer documentation. Cannafull Spectrum Solutions cannot guarantee inclusion of items not confirmed in manufacturer packing specifications. iConnect controller accessories and daisy-chain cables may be sold separately — confirm bundle contents at time of order. Weight is not specified in source data for this SKU.\u003c\/p\u003e\n\n\u003chr style=\"border:none; border-top:1px solid #e0e0e0; margin:32px 0;\"\u003e\n\n\u003ch2 style=\"color:#333333; font-size:1.45em; margin-bottom:14px;\"\u003eRegional Compliance \u0026amp; Deployment Notes\u003c\/h2\u003e\n\n\u003cul style=\"color:#000000; font-size:0.95em; padding-left:20px; margin-bottom:14px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eU.S. Market Certification:\u003c\/strong\u003e The FC-1200W carries ETL listing, confirming compliance with applicable U.S. electrical safety standards as tested by Intertek. ETL-listed fixtures are accepted by most U.S. Authorities Having Jurisdiction (AHJ) for commercial facility electrical inspections.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNEC Compliance:\u003c\/strong\u003e Installation must comply with the National Electrical Code (NEC) and applicable local amendments. Circuit sizing, grounding, and overcurrent protection must be specified by a licensed electrician based on the fixture's published amperage draw: 6.635A at AC120V, 3.266A at AC240V, 2.847A at AC277V.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eState-Level Licensing:\u003c\/strong\u003e Licensed cannabis cultivation facilities must verify that fixture specifications — including wattage, coverage area, and control architecture — comply with state-specific cultivation license conditions and canopy measurement methodologies. Compliance obligations vary by state regulatory framework.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHVAC and Building Permits:\u003c\/strong\u003e The fixture's 4,094 BTU\/hr thermal output contribution may trigger HVAC modification requirements subject to local mechanical permits. Consult a licensed mechanical engineer and local building department before deploying fleet quantities in a new or modified facility.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRoHS Compliance:\u003c\/strong\u003e The FC-1200W carries RoHS certification, confirming restriction of hazardous substances in the fixture's electronic components. This is relevant for facilities subject to environmental compliance audits or operating under sustainability reporting requirements.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShipping Jurisdiction:\u003c\/strong\u003e All sales and shipments through Cannafull Spectrum Solutions are limited to the contiguous 48 United States. No shipments to U.S. territories, Alaska, Hawaii, or international destinations are available through this channel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp style=\"font-size:0.85em; color:#666;\"\u003eCompliance information is provided for general reference only and does not constitute legal, electrical, or regulatory advice. Cannafull Spectrum Solutions makes no representations regarding the suitability of this fixture for any specific licensed facility's regulatory requirements. Operators are responsible for verifying compliance with all applicable federal, state, and local regulations prior to installation and operation.\u003c\/p\u003e","brand":"Mars Hydro","offers":[{"title":"Default Title","offer_id":44237274087559,"sku":"MH-FC-1200W","price":1019.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/4450\/4455\/files\/2024-new-mars-hydro-fc-1200w-evo-led-grow-light-2.jpg?v=1774162724","url":"https:\/\/cannafullspec.com\/es\/products\/mars-hydro-fc-1200w-samsung-lm301h-evo","provider":"CannaFull Spectrum Solutions","version":"1.0","type":"link"}