{"product_id":"alien-hydroponics-v-system-vortex-water-pump-1100w-120v-17700-l-h","title":"Bomba de agua Vortex V-SYSTEM de Alien Hydroponics, 1100 W, 120 V, 17 700 l\/h","description":"\u003cdiv class=\"geo-summary\" style=\"background:#f8f9fa; border-left:4px solid #333; padding:20px 24px; margin-bottom:28px; border-radius:4px;\"\u003e\n  \u003cp style=\"margin:0 0 10px 0; color:#333333; font-size:1em;\"\u003eThe V-SYSTEM Vortex Water Pump 1100W 120V is a high-volume submersible circulation pump engineered for craft operators running reservoir-fed, top-feed, or drain-to-waste irrigation systems who need reliable, high-flow delivery without manual intervention.\u003c\/p\u003e\n  \u003cul style=\"margin:10px 0 14px 0; padding-left:20px; color:#000000;\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eOutcome:\u003c\/strong\u003e Consistent 17,700 l\/h flow rate sustaining uniform nutrient delivery across irrigation infrastructure\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eReplaces:\u003c\/strong\u003e Undersized or mismatched pumps that introduce flow variance and require constant monitoring\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Reservoir systems, recirculating top-feed arrays, and drain-to-waste configurations in licensed production facilities\u003c\/li\u003e\n  \u003c\/ul\u003e\n  \u003cp style=\"margin:8px 0 4px 0; font-weight:bold; color:#333333; letter-spacing:0.04em;\"\u003eFACTORY-AUTHORIZED DEALER — CANNAFULL SPECTRUM SOLUTIONS\u003c\/p\u003e\n  \u003cp style=\"margin:0; color:#555; font-size:0.92em;\"\u003eDeployed in licensed commercial facilities across the United States.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp style=\"color:#333333; font-size:0.95em; margin-bottom:32px;\"\u003e\u003cstrong\u003eQuick Spec:\u003c\/strong\u003e 1100W | 120V | 17,700 l\/h flow rate | SKU: BD101-5012 | $420.00 USD\u003c\/p\u003e\n\n\u003ch2 style=\"text-align:center; color:#333333; font-size:1.6em; margin-bottom:24px;\"\u003ePrecision Control in Any Space\u003c\/h2\u003e\n\n\u003cp style=\"color:#000000; margin-bottom:18px;\"\u003eEvery irrigation system has a weak link, and in most craft operations that weak link is the pump. When flow rates are inconsistent — surging under load, dropping off mid-cycle, or simply undersized for the reservoir volume — the entire feed program becomes unreliable. Nutrient solution arrives at the wrong concentration, at the wrong time, or not at all. Root zones dry unevenly. Canopy response diverges. The operator compensates manually, adjusting schedules and chasing symptoms rather than running a repeatable process. The equipment is not working with you; it is generating variance that compounds with every irrigation cycle.\u003c\/p\u003e\n\n\u003cp style=\"color:#000000; margin-bottom:18px;\"\u003eAfter integrating a properly rated pump into the system, the irrigation infrastructure behaves predictably. Reservoir drawdown follows a known schedule. Top-feed lines deliver consistent pressure across every emitter. Drain-to-waste cycles complete on time without residual pooling or dry zones. The operator stops troubleshooting flow and starts managing the crop. Scheduling becomes a fixed variable rather than a daily negotiation with underperforming equipment.\u003c\/p\u003e\n\n\u003cp style=\"color:#000000; margin-bottom:28px;\"\u003eThe V-SYSTEM Vortex Water Pump achieves this through a 1100W motor operating on standard 120V infrastructure, producing a verified flow rate of 17,700 l\/h — sufficient to service high-volume reservoir systems and multi-zone top-feed arrays without pressure drop across the distribution network. The vortex pump architecture maintains consistent hydraulic output under the variable head pressures common in vertically staged or multi-tier irrigation configurations. In practical terms, the V-SYSTEM Vortex Water Pump delivers 17,700 l\/h of sustained flow at 1100W draw on a 120V circuit, providing the hydraulic capacity to anchor a full-scale craft irrigation system without supplemental pumping stages.\u003c\/p\u003e\n\n\u003ch2 style=\"color:#333333; font-size:1.35em; margin-bottom:16px;\"\u003eWhere This Belongs (and Doesn't)\u003c\/h2\u003e\n\n\u003cp style=\"color:#666; font-style:italic; font-size:0.92em; margin-bottom:18px;\"\u003eElectrical installation must comply with local codes. Confirm circuit capacity before deployment. This pump draws 1100W at 120V — verify dedicated circuit availability with a licensed electrician before connecting to existing infrastructure.\u003c\/p\u003e\n\n\u003cdiv style=\"display:flex; gap:24px; flex-wrap:wrap; margin-bottom:28px;\"\u003e\n  \u003cdiv style=\"flex:1; min-width:220px; background:#f8f9fa; border-left:4px solid #333; padding:16px 18px; border-radius:4px;\"\u003e\n    \u003ch3 style=\"color:#333333; font-size:1em; margin:0 0 10px 0;\"\u003eDesigned For\u003c\/h3\u003e\n    \u003cul style=\"margin:0; padding-left:18px; color:#000000; font-size:0.95em;\"\u003e\n      \u003cli\u003eHigh-volume reservoir circulation and top-feed irrigation systems\u003c\/li\u003e\n      \u003cli\u003eDrain-to-waste configurations requiring timed, high-flow delivery cycles\u003c\/li\u003e\n      \u003cli\u003eMulti-zone distribution networks where consistent head pressure is critical\u003c\/li\u003e\n      \u003cli\u003eCraft-scale production facilities running 120V single-phase electrical infrastructure\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"flex:1; min-width:220px; background:#fff3f3; border-left:4px solid #cc0000; padding:16px 18px; border-radius:4px;\"\u003e\n    \u003ch3 style=\"color:#333333; font-size:1em; margin:0 0 10px 0;\"\u003eNot Recommended For\u003c\/h3\u003e\n    \u003cul style=\"margin:0; padding-left:18px; color:#000000; font-size:0.95em;\"\u003e\n      \u003cli\u003eLow-flow applications where 17,700 l\/h exceeds system design capacity\u003c\/li\u003e\n      \u003cli\u003e240V-only electrical environments without step-down conversion\u003c\/li\u003e\n      \u003cli\u003eDry-run or intermittent-duty applications not suited to continuous submersible operation\u003c\/li\u003e\n      \u003cli\u003eSystems without adequate reservoir volume to sustain rated flow without cavitation\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch2 style=\"color:#333333; font-size:1.35em; margin-bottom:16px;\"\u003eHow It Works\u003c\/h2\u003e\n\n\u003cp style=\"color:#000000; margin-bottom:18px;\"\u003eThe V-SYSTEM Vortex Water Pump operates on a vortex impeller design, which distinguishes it from standard centrifugal pump architectures. In a vortex configuration, the impeller sits recessed within the pump casing rather than directly in the flow path. This geometry creates a rotating fluid vortex that draws liquid through the pump body without the impeller making direct contact with the primary flow stream. The practical result is a pump that handles particulate-laden nutrient solution — including undissolved mineral content common in hard-water reservoirs — without the clogging and impeller wear that degrades standard centrifugal units over time.\u003c\/p\u003e\n\n\u003cp style=\"color:#000000; margin-bottom:18px;\"\u003eAt 1100W on a 120V circuit, the motor delivers the torque necessary to sustain 17,700 l\/h across the variable head pressures introduced by vertical lift, long distribution runs, and multi-emitter top-feed manifolds. The 120V operating voltage means the pump integrates directly into standard facility electrical infrastructure without requiring dedicated 240V circuits or transformer stages. Flow output remains consistent across the operating range, providing the hydraulic stability that irrigation scheduling depends on. In practical terms, the V-SYSTEM Vortex Water Pump delivers 17,700 l\/h at 1100W on 120V, with a vortex impeller architecture that sustains rated output in nutrient-solution environments without the particulate sensitivity of standard centrifugal designs.\u003c\/p\u003e\n\n\u003ch2 style=\"color:#333333; font-size:1.35em; margin-bottom:16px;\"\u003eCommercial Assurance\u003c\/h2\u003e\n\n\u003cdiv style=\"background:#f0f7ff; border-left:4px solid #007bff; padding:18px 22px; margin-bottom:28px; border-radius:4px;\"\u003e\n  \u003cp style=\"color:#000000; margin:0 0 12px 0;\"\u003eCannafull Spectrum Solutions is a factory-authorized dealer for V-SYSTEM products. Every unit sold through this listing is sourced through authorized distribution channels and is eligible for manufacturer support through proper channels.\u003c\/p\u003e\n  \u003cul style=\"margin:0; padding-left:20px; color:#000000;\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAuthorized Sourcing:\u003c\/strong\u003e Units ship from verified distributor inventory — no gray-market or parallel-import stock\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWarranty Coverage:\u003c\/strong\u003e Warranty terms are governed by V-SYSTEM \/ Alien Hydroponics manufacturer policy; contact Cannafull Spectrum Solutions for current warranty documentation specific to SKU BD101-5012\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSupport Access:\u003c\/strong\u003e Pre-sale and post-sale technical support available through Cannafull Spectrum Solutions for system integration questions\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eLocal Availability:\u003c\/strong\u003e Available for in-person pickup at our Longmont location — contact us to confirm stock before traveling\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003ch2 style=\"color:#333333; font-size:1.35em; margin-bottom:16px;\"\u003eSystem Integration\u003c\/h2\u003e\n\n\u003cul style=\"color:#000000; padding-left:22px; margin-bottom:28px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReservoir Sizing:\u003c\/strong\u003e Match reservoir volume to pump flow rate — at 17,700 l\/h, the system requires sufficient reservoir capacity to prevent rapid drawdown and dry-run risk during extended irrigation cycles\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDistribution Manifold:\u003c\/strong\u003e Use appropriately rated PVC or HDPE manifold and fittings sized for the pump's output pressure to prevent joint failure and flow restriction\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTimer and Controller Compatibility:\u003c\/strong\u003e Integrate with a dedicated irrigation timer or controller rated for 1100W resistive load at 120V to enable automated cycle scheduling\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInline Filtration:\u003c\/strong\u003e Install a pre-pump strainer or inline filter on the intake side to protect the impeller from large debris while preserving the pump's native particulate tolerance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrical Circuit:\u003c\/strong\u003e Dedicate a 15A or 20A 120V circuit to this pump; do not share the circuit with other high-draw equipment to prevent nuisance tripping and voltage sag\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#333333; font-size:1.2em; margin-bottom:10px;\"\u003eFacility Integration Data\u003c\/h3\u003e\n\n\u003cp style=\"color:#000000; margin-bottom:18px;\"\u003eThe table below provides a reference framework for operators evaluating the V-SYSTEM Vortex Water Pump across single-unit and multi-unit facility deployments, including electrical load aggregation and capital cost at MAP pricing.\u003c\/p\u003e\n\n\u003cdiv style=\"background:#f0f7ff; border-left:4px solid #007bff; padding:18px 22px; margin-bottom:28px; border-radius:4px;\"\u003e\n  \u003ch4 style=\"color:#333333; margin:0 0 14px 0;\"\u003eFleet Deployment Reference — V-SYSTEM Vortex Water Pump 1100W\u003c\/h4\u003e\n  \u003ctable style=\"width:100%; border-collapse:collapse; font-size:0.93em; color:#000000;\"\u003e\n    \u003cthead\u003e\n      \u003ctr style=\"background:#007bff; color:#ffffff;\"\u003e\n        \u003cth style=\"padding:9px 12px; text-align:left; border:1px solid #cce0ff;\"\u003eFleet Size\u003c\/th\u003e\n        \u003cth style=\"padding:9px 12px; text-align:left; border:1px solid #cce0ff;\"\u003eAggregate Draw (W)\u003c\/th\u003e\n        \u003cth style=\"padding:9px 12px; text-align:left; border:1px solid #cce0ff;\"\u003eTotal Flow Capacity (l\/h)\u003c\/th\u003e\n        \u003cth style=\"padding:9px 12px; text-align:left; border:1px solid #cce0ff;\"\u003eCapital Cost (MAP)\u003c\/th\u003e\n        \u003cth style=\"padding:9px 12px; text-align:left; border:1px solid #cce0ff;\"\u003eSezzle Option (5 payments)\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr style=\"background:#ffffff;\"\u003e\n        \u003ctd style=\"padding:8px 12px; border:1px solid #cce0ff;\"\u003e1 Unit\u003c\/td\u003e\n        \u003ctd style=\"padding:8px 12px; border:1px solid #cce0ff;\"\u003e1,100W\u003c\/td\u003e\n        \u003ctd style=\"padding:8px 12px; border:1px solid #cce0ff;\"\u003e17,700 l\/h\u003c\/td\u003e\n        \u003ctd style=\"padding:8px 12px; border:1px solid #cce0ff;\"\u003e$420.00\u003c\/td\u003e\n        \u003ctd style=\"padding:8px 12px; border:1px solid #cce0ff;\"\u003e$84.00 x 5\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0f7ff;\"\u003e\n        \u003ctd style=\"padding:8px 12px; border:1px solid #cce0ff;\"\u003e10 Units\u003c\/td\u003e\n        \u003ctd style=\"padding:8px 12px; border:1px solid #cce0ff;\"\u003e11,000W\u003c\/td\u003e\n        \u003ctd style=\"padding:8px 12px; border:1px solid #cce0ff;\"\u003e177,000 l\/h\u003c\/td\u003e\n        \u003ctd style=\"padding:8px 12px; border:1px solid #cce0ff;\"\u003e$4,200.00\u003c\/td\u003e\n        \u003ctd style=\"padding:8px 12px; border:1px solid #cce0ff;\"\u003e$840.00 x 5\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#ffffff;\"\u003e\n        \u003ctd style=\"padding:8px 12px; border:1px solid #cce0ff;\"\u003e20 Units\u003c\/td\u003e\n        \u003ctd style=\"padding:8px 12px; border:1px solid #cce0ff;\"\u003e22,000W\u003c\/td\u003e\n        \u003ctd style=\"padding:8px 12px; border:1px solid #cce0ff;\"\u003e354,000 l\/h\u003c\/td\u003e\n        \u003ctd style=\"padding:8px 12px; border:1px solid #cce0ff;\"\u003e$8,400.00\u003c\/td\u003e\n        \u003ctd style=\"padding:8px 12px; border:1px solid #cce0ff;\"\u003e$1,680.00 x 5\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr style=\"background:#f0f7ff;\"\u003e\n        \u003ctd style=\"padding:8px 12px; border:1px solid #cce0ff;\"\u003e50 Units\u003c\/td\u003e\n        \u003ctd style=\"padding:8px 12px; border:1px solid #cce0ff;\"\u003e55,000W\u003c\/td\u003e\n        \u003ctd style=\"padding:8px 12px; border:1px solid #cce0ff;\"\u003e885,000 l\/h\u003c\/td\u003e\n        \u003ctd style=\"padding:8px 12px; border:1px solid #cce0ff;\"\u003e$21,000.00\u003c\/td\u003e\n        \u003ctd style=\"padding:8px 12px; border:1px solid #cce0ff;\"\u003e$4,200.00 x 5\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n  \u003cp style=\"font-size:0.82em; color:#555; margin:10px 0 0 0;\"\u003eElectrical load figures are aggregate nameplate draw. Actual facility load calculations must account for simultaneous operation schedules, circuit derating, and local electrical code requirements. Consult a licensed electrician for facility-level load planning.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2 style=\"color:#333333; font-size:1.35em; margin-bottom:16px;\"\u003eOperator Field Notes\u003c\/h2\u003e\n\n\u003cul style=\"color:#000000; padding-left:22px; margin-bottom:28px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVerify circuit capacity before installation:\u003c\/strong\u003e At 1100W on 120V, this pump draws approximately 9.2A continuous — confirm your circuit breaker and wiring gauge are rated for sustained load before connecting\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrime the pump before first run:\u003c\/strong\u003e Ensure the pump body is fully submerged and the intake is clear of air pockets before energizing — dry-starting a submersible pump will damage the seal and void any applicable warranty\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMonitor reservoir level during operation:\u003c\/strong\u003e At 17,700 l\/h, reservoir drawdown is rapid — install a float switch or low-level cutoff to protect the pump from running dry during extended drain-to-waste cycles\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInspect intake strainer on a scheduled basis:\u003c\/strong\u003e Even with vortex impeller tolerance for particulates, accumulated debris on the intake screen will reduce effective flow rate and increase motor load over time\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAccount for head pressure in system design:\u003c\/strong\u003e Rated flow of 17,700 l\/h is measured at zero head — actual delivered flow will be lower as vertical lift and distribution run length increase; size your manifold accordingly\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLocal pickup available:\u003c\/strong\u003e If you are evaluating this unit for an active build, in-person pickup at the Longmont location allows for same-day integration — contact Cannafull Spectrum Solutions to confirm availability before visiting\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"color:#333333; font-size:1.35em; margin-bottom:16px;\"\u003eOperator FAQ\u003c\/h2\u003e\n\n\u003cdiv itemscope itemtype=\"https:\/\/schema.org\/FAQPage\" style=\"margin-bottom:28px;\"\u003e\n\n  \u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border-bottom:1px solid #e0e0e0; padding:12px 0;\"\u003e\n    \u003csummary itemprop=\"name\" style=\"font-weight:bold; color:#333333; cursor:pointer;\"\u003eQ: What is the flow rate of the V-SYSTEM Vortex Water Pump 1100W, and how is it measured?\u003c\/summary\u003e\n    \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n      \u003cp itemprop=\"text\" style=\"color:#000000; margin:10px 0 0 0;\"\u003eA: The rated flow rate is 17,700 l\/h. This figure represents maximum output at zero head pressure — meaning no vertical lift and no distribution resistance. Actual delivered flow in a working irrigation system will be lower depending on the height the pump must lift the solution and the length and diameter of the distribution lines. Always factor head pressure into your system design when sizing manifolds and emitters.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border-bottom:1px solid #e0e0e0; padding:12px 0;\"\u003e\n    \u003csummary itemprop=\"name\" style=\"font-weight:bold; color:#333333; cursor:pointer;\"\u003eQ: Does this pump require a dedicated electrical circuit?\u003c\/summary\u003e\n    \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n      \u003cp itemprop=\"text\" style=\"color:#000000; margin:10px 0 0 0;\"\u003eA: Yes. The V-SYSTEM Vortex Water Pump draws 1100W at 120V, which equates to approximately 9.2A of continuous load. A dedicated 15A or 20A 120V circuit is strongly recommended. Sharing a circuit with other high-draw equipment risks nuisance tripping, voltage sag, and potential damage to the pump motor. Consult a licensed electrician to confirm circuit suitability before installation.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border-bottom:1px solid #e0e0e0; padding:12px 0;\"\u003e\n    \u003csummary itemprop=\"name\" style=\"font-weight:bold; color:#333333; cursor:pointer;\"\u003eQ: Why does the V-SYSTEM use a vortex impeller design instead of a standard centrifugal pump?\u003c\/summary\u003e\n    \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n      \u003cp itemprop=\"text\" style=\"color:#000000; margin:10px 0 0 0;\"\u003eA: A vortex impeller sits recessed within the pump casing rather than directly in the primary flow path. This means the impeller creates a rotating fluid vortex that moves liquid through the pump without direct contact between the impeller and the bulk flow stream. The result is significantly higher tolerance for particulate-laden nutrient solution — including mineral deposits and undissolved solids common in hard-water environments — compared to standard centrifugal designs where the impeller is fully exposed to the flow and susceptible to clogging and abrasive wear.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border-bottom:1px solid #e0e0e0; padding:12px 0;\"\u003e\n    \u003csummary itemprop=\"name\" style=\"font-weight:bold; color:#333333; cursor:pointer;\"\u003eQ: Can this pump be used in a drain-to-waste irrigation system?\u003c\/summary\u003e\n    \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n      \u003cp itemprop=\"text\" style=\"color:#000000; margin:10px 0 0 0;\"\u003eA: Yes. The V-SYSTEM Vortex Water Pump is well-suited to drain-to-waste configurations where timed, high-volume delivery cycles are required. Because the pump operates at 17,700 l\/h, reservoir drawdown during active cycles is rapid — operators running drain-to-waste systems should install a float switch or low-level cutoff to prevent the pump from running dry at the end of a cycle, which can damage the motor seal.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border-bottom:1px solid #e0e0e0; padding:12px 0;\"\u003e\n    \u003csummary itemprop=\"name\" style=\"font-weight:bold; color:#333333; cursor:pointer;\"\u003eQ: Is the V-SYSTEM Vortex Water Pump available for local pickup?\u003c\/summary\u003e\n    \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n      \u003cp itemprop=\"text\" style=\"color:#000000; margin:10px 0 0 0;\"\u003eA: Yes. The V-SYSTEM Vortex Water Pump 1100W is available for in-person pickup at the Cannafull Spectrum Solutions location in Longmont, Colorado. Contact us before visiting to confirm current stock availability, as inventory levels can change. Same-day pickup is possible when stock is confirmed on hand.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\" style=\"border-bottom:1px solid #e0e0e0; padding:12px 0;\"\u003e\n    \u003csummary itemprop=\"name\" style=\"font-weight:bold; color:#333333; cursor:pointer;\"\u003eQ: What financing options are available for this pump?\u003c\/summary\u003e\n    \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n      \u003cp itemprop=\"text\" style=\"color:#000000; margin:10px 0 0 0;\"\u003eA: The V-SYSTEM Vortex Water Pump is available through Sezzle financing at checkout, structured as 5 payments of $84.00 USD. Sezzle eligibility is subject to approval at the time of purchase. The full unit price is $420.00 USD at MAP pricing. For multi-unit orders or fleet procurement inquiries, contact Cannafull Spectrum Solutions directly to discuss available options.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/details\u003e\n\n\u003c\/div\u003e\n\n\u003ch2 style=\"color:#333333; font-size:1.35em; margin-bottom:16px;\"\u003eShipping \u0026amp; Logistics\u003c\/h2\u003e\n\n\u003cul style=\"color:#000000; padding-left:22px; margin-bottom:18px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShipping Territory:\u003c\/strong\u003e Cannafull Spectrum Solutions ships within the contiguous 48 United States only. Orders outside this territory cannot be fulfilled through this listing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLocal Pickup:\u003c\/strong\u003e Available at our Longmont, Colorado location. Contact us to confirm stock before visiting. Pickup orders are not subject to shipping charges.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReturns:\u003c\/strong\u003e Returns are accepted subject to product condition and return authorization. Contact Cannafull Spectrum Solutions within the applicable return window to initiate a return request. Items must be in original, uninstalled condition to qualify.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRestocking Fee:\u003c\/strong\u003e Returns of non-defective items are subject to a restocking fee of up to 25% per our Return Policy. Review full terms at cannafullspec.com\/pages\/return-policy before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp style=\"color:#333333; font-weight:bold; margin-bottom:28px;\"\u003eQuestions about shipping, availability, or order status? Contact Cannafull Spectrum Solutions directly before placing your order.\u003c\/p\u003e\n\n\u003ch2 style=\"color:#333333; font-size:1.35em; margin-bottom:16px;\"\u003eWhat's in the Box\u003c\/h2\u003e\n\n\u003cul style=\"color:#000000; padding-left:22px; margin-bottom:12px;\"\u003e\n  \u003cli\u003e1x V-SYSTEM Vortex Water Pump 1100W 120V (SKU: BD101-5012)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp style=\"font-size:0.88em; color:#666; margin-bottom:28px;\"\u003e\u003cem\u003eNote: Included accessories, mounting hardware, fittings, and documentation are not specified in available source data. Contact Cannafull Spectrum Solutions or refer to manufacturer packaging documentation to confirm complete box contents before installation planning.\u003c\/em\u003e\u003c\/p\u003e\n\n\u003ch2 style=\"color:#333333; font-size:1.35em; margin-bottom:16px;\"\u003eRegional Compliance \u0026amp; Deployment Notes\u003c\/h2\u003e\n\n\u003cul style=\"color:#000000; padding-left:22px; margin-bottom:12px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eElectrical Code Compliance:\u003c\/strong\u003e Installation of this pump must comply with the National Electrical Code (NEC) and applicable local amendments. Dedicated circuit requirements, GFCI protection in wet locations, and conduit specifications vary by jurisdiction — verify requirements with a licensed electrician before installation.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLicensed Facility Use:\u003c\/strong\u003e This product is sold for use in licensed commercial production facilities operating under applicable state and local regulations. Operators are responsible for ensuring their facility's water and electrical systems meet the requirements of their operating license.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eState-Level Electrical Inspection:\u003c\/strong\u003e Some states require electrical inspection and permit for new circuit installations associated with commercial equipment. Confirm permit requirements with your local authority having jurisdiction (AHJ) before proceeding.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWater System Regulations:\u003c\/strong\u003e Irrigation and reservoir systems in licensed production facilities may be subject to water use reporting, discharge regulations, or runoff containment requirements depending on state and municipal rules. Operators are responsible for compliance with applicable water management regulations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShipping Jurisdiction:\u003c\/strong\u003e This product is available for sale and shipment within the contiguous 48 United States only through Cannafull Spectrum Solutions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp style=\"font-size:0.85em; color:#666;\"\u003eCannafull Spectrum Solutions provides this compliance information as a general reference only. It does not constitute legal or engineering advice. Operators are solely responsible for ensuring their installations meet all applicable federal, state, and local regulatory requirements. Consult qualified legal, electrical, and compliance professionals for jurisdiction-specific guidance.\u003c\/p\u003e","brand":"Alien Hydroponics","offers":[{"title":"Default Title","offer_id":41851345830023,"sku":"BD101-5012","price":420.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0587\/4450\/4455\/files\/V_PUMP_370_8a948150-901e-41e3-96e7-eda8373451dd.jpg?v=1774584647","url":"https:\/\/cannafullspec.com\/es\/products\/alien-hydroponics-v-system-vortex-water-pump-1100w-120v-17700-l-h","provider":"CannaFull Spectrum Solutions","version":"1.0","type":"link"}